LOCATING DEAD CIRCUITS

a dead circuit caused by a tripped breaker can be located by fol-
lowing the circuit’s neutral line. connect power from any energized 
line and return it through the neutral of the dead circuit. You can 
then trace the neutral wire to the panel.

notE: You may also find the source or hot wire breaker with this 
process, however, the same panel will likely contain both circuits. to 
verify this, remove the panel trim and test the neutral wire.

FINDING SHORTS TO GROUND

typical configuration is shown below. confirm that the transmit-
ter lED is flashing then follow the wire until the signal disappears, 
indicating the location of the short.

TOLL FREE CUSTOMER SERVICE  

1.800.999.9952

TRANSMITTER

BATT

TO ANY HOT

OR BATTERY

TO NEUTRAL

USE CLIP LEAD AND AC BLADE ADAPTER

DEAD 

CIRCUIT

Содержание POWER TRACE PTL610

Страница 1: ...POWER TRACETM TASCO INC Instruction Manual PTL610...

Страница 2: ...CETM OPERATES The Power TraceTM is composed of two primary components the Receiver and the Transmitter When the Transmitter is connected to any electrical line up to 600 Volts it draws a very small cu...

Страница 3: ...E 1 800 999 9952 Read and understand this material before operating or servicing this equipment Failure to understand how to safely operate this instrument can result in an accident causing serious in...

Страница 4: ...ized line 2 Push the Receiver button The unit will beep and the green power LED next to the button will light If the green LED flashes remove and replace the 9 volt battery The Receiver will also indi...

Страница 5: ...breaker panel trim and test the wires as shown Important Panel trim can distort the signal when locating breakers on the outside corners of the panel This can cause stronger signal level on the adjac...

Страница 6: ...eiver to the appropriate signal level The signal strength will increase and the variable signal LEDs will adjust as you get closer to the signal wire This creates the most accurate reading possible ba...

Страница 7: ...ource or hot wire breaker with this process however the same panel will likely contain both circuits To verify this remove the panel trim and test the neutral wire FINDING SHORTS TO GROUND Typical con...

Страница 8: ...14 15 THIS PAGE INTENTIONALLY LEFT BLANK TOLL FREE CUSTOMER SERVICE 1 800 999 9952...

Страница 9: ...not allow limitations of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may also have rights which vary...

Отзывы: