9 – Various information displays
Sonicview 16/24 Error Screen SYSTEM error/alert message list
Error/alert type
Message
Meaning
Note
System Clock Error
“Master clock name” clock has no
signal. Switched to Internal.
There is no signal from the master
clock.
Master clock name:
WORD
Dante
SLOT 1 (slot signal type)
SLOT 2 (slot signal type)
Slot signal types:
AES, Dante, MADI
“Master clock name” clock is
unlocked. Switched to Internal.
The master clock is unlocked.
“Master clock name” clock regained.
The master clock has been
regained (locking is possible
again after becoming unlocked).
“Master clock name” clock regained.
Can be re-synced to “Master clock
name”.
The master clock has been
regained (locking is possible
again after becoming unlocked).
(message that appears at the top
of the screen)
“Master clock name” clock is locked. The master clock is locked.
Slot Card Error
SLOT [slot number] [card name] was
removed.
The expansion card was removed. Slot number: 1/2
Card name:
i
IF-AE16 (AES)
i
IF-AN16/OUT (Analog Out)
i
IF-DA64 (Dante)
i
IF-MA64/BN (MADI)
i
IF-MA64/EX (MADI)
SLOT [slot number] [card name]
failure.
Trouble was detected with the
expansion card.
Internal Dante Error
Dante Module Unavailable.
The built-in Dante module is in
an unusable state (in safe mode/
updating).
Dante Module Available.
The built-in Dante module is in a
usable state.
Device Temperature Error
SYSTEM is too HOT.
Increase FAN speed.
The internal temperature of the
unit has risen.
Increase the speed of the cooling
fan.
CPU is too HOT.
Increase FAN speed.
The temperature of the CPU has
risen.
Increase the speed of the cooling
fan.
DSP is too HOT.
Increase FAN speed.
The temperature of the DSP has
risen.
Increase the speed of the cooling
fan.
SYSTEM is too COLD.
The internal temperature of the
unit is too low.
CPU is too COLD.
The temperature of the CPU is
too low.
DSP is too COLD.
The temperature of the DSP is
too low.
SYSTEM temperature normal.
The internal temperature of the
unit has returned to the proper
range.
CPU temperature normal.
The temperature of the CPU has
returned to the proper range.
DSP temperature normal.
The temperature of the DSP has
returned to the proper range.
Cooling FAN Error
Cooling FAN failure.
The cooling fan has stopped.
Cooling FAN in motion.
The cooling fan has started
moving.
148
TASCAM Sonicview 16/Sonicview 24