– 22 –
Troubleshooting
Specifications
Format:
MiniDisc digital audio system
Recording system:
Magnetic field modulation overwrite
system
Recording/playback time:
Stereo: 74 minutes max.
Mono: 148 minutes max.
Sampling frequency:
44.1 kHz
Compression system:
ATRAC (Adaptive
TRansform Acoustic Coding)
Dynamic range:
More than 94 dB (playback, 1 kHz,
A filter)
Total harmonic distortion:
Less than 0.013%
Number of channels:
2 (stereo),1 (mono)
Frequency response:
20 Hz – 20 kHz ± 0.5 dB (playback)
Signal-to-noise ratio:
More than 94 dB (playback, A filter)
Analog input/output connectors:
Input:
Balanced: XLR, +4 dBu (ref.),
10 kohms
Unbalanced: RCA, –10 dBV (ref.),
`
50 kohms
Output:
Balanced: XLR, +4 dBu (ref.),
150 ohms
Unbalanced: RCA, –10 dBV (ref.),
600 ohms
Power supply:
120 V AC, 60 Hz
(U.S.A./Canada model),
230 V AC, 50 Hz
(Europe/General export model),
240 V AC, 50 Hz
(Australia model)
Headphones output:
Max. 25 mW + 25 mW,
32 ohms
Digital input/output connectors:
Input 1, 2:
TOS (EIAJ RC-5720), IEC60958
Type II (S/PDIF)
Output:
TOS (EIAJ RC-5720), IEC60958
Type II (S/PDIF)
Remote connector:
KEYBOARD connector: Mini DIN 6pin
Power consumption:
13 W
Dimensions (W x H x D):
482.6 x 94 x 313 (mm)
Weight:
5.5 kg
Accessories:
Remote control unit (RC-32) x 1
Battery (SUM-3, "AA", "R6" type) x 2
Lettering guide x 1
Rack mounting screw kit x 1
…
Improvements may result in specifi-
cations or feature changes without
notice.
…
Photos and illustrations may differ
slightly from production models.
* US and foreign patents licensed from
Dolby Laboratories Licensing Corpora-
tion.
If you have any problems with the deck, please check the following before calling for service.
If the trouble persists, please consult your dealer or nearest TEAC service agent.
Problem
Remedy
No operations are possible.
The MD is dirty or damaged. If "Disc Error !" is display-
ed in this case, replace the MD with another disc.
Playback will not start.
Check if power is supplied.
"Blank Disc" is displayed if the MD contains no record-
ed data. "No Track !!" is displayed if no tracks have been
recorded on the disc. Replace the MD with a pre-
recorded MD.
When "UTOC Error !" is displayed, replace the MD with
another disc.
There may be condensation inside the deck. In this case,
eject the MD and leave the deck on for a few hours.
Recording will not start.
When "Protected !!" is displayed, the MD is protected
against accidental erasure. Slide the accidental
erasure protection tab to close the hole. A playback-only
MD is loaded. Replace the MD with a recordable one.
When "D-IN UNLOCK !" is displayed and the source audio
is not input, connect the source through digital connection
or record the audio using the analog input.
Timer recording is unavailable.
After timer recording, turn the power back on within 3 or
4 days and eject the MD. If the deck is left off for a long
time, the recorded contents may disappear.
When "Disc Full !!" is displayed, the disc has no remain-
ing time available for recording. Erase unnecessary
tracks or use another MD.
When "Rec Error !!" is displayed, there is an error in
recording. Restart recording from the beginning.
Too much noise.
Do not operate this deck near a TV.
ª
U-TOC
Editing recorded tracks is easy with
recordable MiniDiscs. Information about
the recorded tracks (start address, end
address, title, etc.) is recorded in the U-
TOC (User Table Of Contents) area. You can
edit tracks simply by rewriting this data.
Music Data
U-TOC
…
If normal operation cannot be recovered, unplug the power cord from the outlet and plug it
again.