7 – Advanced operations–Shuttle operations
44
TASCAM DA-98HR
2
Use the
Ó
and
Á
keys to move the cursor to
the left parameter (
Vari
or
Fix
).
3
Use the
§
and
¶
keys to select
Vari
rather
than
Fix
, and the
VARI SPEED
indicator by
the tape counter
will light.
4
Move the cursor to the value setting and use
the
§
and
¶
keys to alter the speed in 0.1%
steps.
NOTE
S
The
VARI SPEED
indicator by the tape counter will light
whenever the setting is
Vari
, even if the speed is set to
0.0%
.
If pull up or pull down (Fs shift) is enabled (9.4.1, “Pull up
and pull down (Fs shift)”, vari speed cannot be enabled.
Playback and recording now take place at the new
speed which has just been set.
7.5.2
Resetting the speed to standard
1
Select menu group 0, move the cursor to
Vari Spd
, and press
ENTER
:
2
Move the cursor to the
Vari
field.
3
Use the
§
and
¶
keys to change
Vari
to
Fix
, and the
VARI SPEED
indicator by the
goes out.
NOTE
Remember that the
VARI SPEED
indicator reflects the
status of the Vari/Fix parameter, not the value of the vari-
able speed. If the speed is set to a value other than
0.0%
, and the status is
Fix
, the speed will remain at
the standard value until
Fix
is changed to
Vari
.
7.6
Shuttle operations
The
JOG/SHUTTLE
key and indicator
and shuttle
wheel/jog dial control
“rock and roll” location method on open-reel tape
decks, allowing you to locate a point on tape through
audible cues.
As the knob is moved from the center detented posi-
tion, the shuttle speed becomes higher.
The variation in speed is not continuous; but as you
turn the knob from the center position, the shuttle
speed changes, following these values (relative to
normal speed): 0.25, 0.5, 1.0, 2.0, 4.0, 8.0. The 1.0
speed is only available when shuttling in the forward
direction.
Shuttle operations are only possible when the
JOG/
SHUTTLE
indicator is lit by pressing the
JOG/
SHUTTLE
key. While shuttling is active, none of the
transport keys are lit.
If the
DATA ENTRY
indicator
is lit when the
JOG/
SHUTTLE
key is pressed, the
DATA ENTRY
indicator
goes out and the dial can then be used for jog
functions.
NOTE
If the jog dial or shuttle wheel remain untouched at the cen-
ter position for 10 seconds, the shuttle mode is disabled,
and the indicator goes off. The
STOP
key lights.
7.6.1
Shuttle monitoring
This is also covered in 5, “Monitoring modes”.
The default behavior of the DA-98HR is that when
shuttling the tape, you can choose whether to monitor
tape or source signals when shuttling, using the
tracks’
INPUT MONITOR
switches.
NOTE
When monitoring in shuttle mode, the monitor signal is
attenuated by 12 dB (to avoid possible damage to ears and
speakers).
When
AUTO MON
,
the
monitoring of any armed tracks will be from the tape,
unless shuttle monitoring is on, in which case, the
monitoring of armed tracks will be source input. The
monitoring of all other (unarmed) tracks can still be
switched on a track-by-track basis using the tracks’
INPUT MONITOR
switches.
Shuttle monitoring is only enabled when
AUTO MON
is on. When
AUTO MON
is off, it has no effect.
1
Select menu group 2, move the cursor to
Shtl Mon
, and press
ENTER
:
2
Use the
§
and
¶
keys to change the setting
between
off
and
on
.
When shuttle monitoring is enabled, the
SHTL
MON
indicator below the tape counter lights.
V a r i
S p e e d
V a r i
+
1 . 4 %
S h u t t l e
M o n i t o r
o f f