background image

PIN 1

GREEN/

WHITE

PIN 2

GREEN/

BLACK

PIN 3

ORANGE/

BLACK

PIN 4

PIN 7

RED/

WHITE

GRAY

PIN 5

PIN 8

BROWN/

WHITE

VIOLET/

WHITE

PIN 6

PIN 9

BROWN

GRAY

RE-ARM (-)

PROGRAMMABLE

Supplies one .75 second pulse when locked and one .75 second pulse 
after remote start shutdown. Factory alarm re-arm/ RAP shutdown.

DISARM (-)

Supplies one .75 second pulse when the unlock button is pressed and 
one .75 second pulse before remote start activation. For factory alarm dis-
arm/ or as computer “wake up”.

AUX #1 

OUTPUT (-)

PROGRAMMABLE

Default-  AUX channel output when the Unlock and START buttons are 
held (no car finder)   Programmable for a (-) Ignition  or (-) Dome Light 
output with the 

 activating car finder mode. 

Unlock and START buttons

N/A

HOOD PIN 

INPUT (-)

       N/A

Connect

 

this wire to the supplied hood pin switch. If ground is detected on 

this input the remote starter will not activate. Programmable for N/C hood 
pin type (Factory hood pin)

HORN 

OUTPUT (-)

PROGRAMMABLE

TACH WIRE 

INPUT (A/C)

Connect this wire to the factory horn wire of the vehicle. This connection 
will provide audible confirmation when programming and when a function 
is performed. 

This wire is

 

used to

 

 to detect when the vehicle has started. The Tach 

source is typically taken from a fuel injector, coil, coil pack or crank 
position sensor. The Tach wire is generally found as the opposite from the 
common wire at the coil or fuel injector.

BRAKE 

SWITCH 

INPUT (+)

 GLOW PLUG 

INPUT (+)

This wire must be connected to the wire at the brake switch that changes 
to 12volts when the brake is pressed. 

Default Gas Mode/ Positive Glow Plug. Programmable.

PIN 1

PIN 1

PURPLE

BLACK

PIN 2

PIN 2

ORANGE

WHITE

PIN 3

RED

PIN 4

RED

PIN 6

PINK

PIN 5

PINK/

WHITE

STARTER 

OUTPUT

SYSTEM 

GROUND

This wire will test 0V with the key off, in the Accessory position and when the 
Ignition is in the on. This wire is 12volts in the start/ crank position only.

Connect to chassis ground.

HEATER  

OUTPUT

PARK LIGHT 

OUTPUT

(SELECTABLE)

This wire will test 0V when key is off, 12volts in the ACC and IGN positions 
and off during the start/ crank position

Connect to the vehicles positive park light wire or change the jumper and 
connect to the vehicle negative park light wire. The default position of the 
jumper is 

Positive Park Light Output.

12v INPUT 30A

Connect to constant 12volts. This input supplies the 12volt power for the 
IGN 1, IGN 2 and Park Light output. 

12v INPUT 30A

Connect to constant 12volts. This input supplies the 12volt power for the 
Accessory and Starter output. 

IGNITION 

OUTPUT

This wire will test 0V in the off and Accessory positions then switch to12volts 
in the Ignition and Start and run position.

SELECTABLE 

OUTPUT

2nd Ignition, Accessory or Start output. Programmable.
Note: This output does not switch to default when the system is reset.

PIN 1

GREEN

PIN 2

N / A

PIN 3

BLUE

(-) LOCK 

OUTPUT

Connect to lock wire from the switch on vehicles with a negative type switch. 
**LOW CURRENT ONLY**

12V + DOOR 

LOCK INVERTER

This output will supply 12volts for a plug-in type door lock module. Do not 
use this input to power-up relays **LOW CURRENT ONLY**

(-) UNLOCK 

OUTPUT

Connect to unlock wire from the switch on vehicles with a negative type 
switch. **LOW CURRENT ONLY**

  

 6-PIN CONNECTOR

  

 9-PIN CONNECTOR

 

  2-PIN CONNECTOR

  3 PIN DOOR LOCK CONNECTOR

SYSTEM PROGRAMMING - 

Menu 1

PAGE 6

INSTALL  MANUAL

 WIRE DESCRIPTION 

SYSTEM PROGRAMMING - 

Menu 1

PAGE 7

INSTALL MANUAL

WIRE DESCRIPTION 

PIN 1

ORANGE

PIN 2

BLACK

PIN 3

N/A

GROUND WHEN

RUNNING

 This wire is used for bypass module activation or adding additional relays to 
be triggered only when the remote starter activates.

GROUND

This wire can be used to supply ground to your bypass module.

  3 PIN BYPASS MODULE CONNECTOR

RS.1

RS.1

Содержание RS.1

Страница 1: ...nterference and 2 This device must accept any interference received including interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the part respon...

Страница 2: ...ark Light Ground Connector 3 Pin Lock Unlock Connector 3 Pin Bypass Module Connector 9 Pin Connector Transmitter Programming Page 8 Programming Remote Transmitters Program Mode Page 9 Enter Program Mo...

Страница 3: ...OWER INPUT RED OUTPUT TO ACTIVATE THE STARTER CIRCUIT PURPLE 12VOLT 30 AMP MAIN POWER INPUT RED OUTPUT TO ACTIVATE ACCESSORY CIRCUIT THE ORANGE AUX 1 OUTPUT HOLD UNLOCK START ORANGE BLACK N A RED WHIT...

Страница 4: ...DESIGNED TO SUPPLY POWER TO DOOR LOCK MODULES DO NOT CONNECT TO RELAYS OVERLOADING THIS OUTPUT WILL DAMAGE THE MODULE FOR USE WITH COMPATIBLE BYPASS MODULES ONLY BY DEFAULT THE SYSTEM COMES WITH THE...

Страница 5: ...g for 15 minutes Hybrid Mode 2 No Tach wire connection This setting will power up the ignition wires pulse the start output for 2 seconds then stay on run for 15 minutes See Program Menu 4 Hybrid Mode...

Страница 6: ...t IGNITION OUTPUT This wire will test 0V in the off and Accessory positions then switch to12volts in the Ignition and Start and run position SELECTABLE OUTPUT 2nd Ignition Accessory or Start output Pr...

Страница 7: ...nect this wire to the supplied hood pin switch If ground is detected on this input the remote starter will not activate Programmable for N C hood pin type Factory hood pin HORN OUTPUT PROGRAMMABLE TAC...

Страница 8: ...he lights turn off and the honk honks 5 times Cycle the Ignition Key ON OFF ON OFF ON Leaving the key ON ENTERING REMOTE PROGRAM MODE The system can lean up to 4 different remote s Each remote to be u...

Страница 9: ...and with horn honks 4 Press and Release the Program Switch to advance through the settings Confirmed by Park Lights Horn Honks LED flashes 5 Press and Hold the Program Switch to change the setting Con...

Страница 10: ...LOCK IGNITION AUTO LOCK UNLOCK IGNITION AUTO LOCK ONLY HORN SETTINGS HORN CHIRPS DISABLED HORN CHIRPS ENABLED DOOR LOCK PULSE OPTIONS DOUBLE UNLOCK SINGLE LOCK DOUBLE LOCK SINGLE UNLOCK SINGLE LOCK SI...

Страница 11: ...ECOND DELAY TO START GAS POSITIVE GLOW PLUG RE ARM OPTIONS PULSE WITH LOCK PULSE AFTER START DEFROST SEAT PULSE WITH LOCK AFTER SHUTDOWN RUNTIME 4 MINUTE RUNTIME PRESS BUTTON ONCE TO START 45 MINUTE R...

Страница 12: ...s and release the Program Button Step 2 The system will respond with three park light flashes and the HORN optional will honk the same number of times as the events in memory Maximum four events four...

Страница 13: ...K BUTTON WILL UNLOCK THE DOORS THEN THE NEXT TIME YOU PRESS THE BUTTON THE DOORS WILL LOCK WHEN PROGRAMMED FOR 2 BUTTON OR LOCK UNLOCK TOGGLE PRESSING UNLOCK AND START AT THE SAME TIME WILL SELECT 4 H...

Страница 14: ...EGATIVE DOOR LOCK LOW CURRENT Ground Ground 12volts 12volts 87 86 85 87a 30 87 86 85 87a 30 Alarm and or Starter Module Door lock Output Blue Green Vehicle s Lock Unlock Switch USE SPDT 12v Relay POSI...

Страница 15: ...or lock Output Blue Green Unlock Resistor Lock Resistor Lock Unlock Switch USE SPDT 12v Relay REVERSE POLARITY DOOR LOCK SYSTEM 12volts 12volts Alarm and or Starter Module Door lock Output Blue Green...

Страница 16: ...website www security soundstream com tech support tech support soundstream com...

Отзывы: