![Taramps SMART 5 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/taramps-0/smart-5/smart-5_instruction-manual_818841011.webp)
The fan and ventilation openings are responsible for cooling the amplifier when it is in
use, so it cannot be obstructed.
CAUTION
Before making any connections to the power terminals, make sure that the negative (-)
of the vehicle battery is disconnected.
CAUTION
3 - POSITIVE POWER SUPPLY:
Use cable of minimum 2/0 AWG direct from the positive battery pole, with fuse
or circuit breaker (230A), as close to it as possible.
In case of power bus bar using, avoid tightening with extenders on the allen wrench, as excessive torque may
break the the terminal.
2 - NEGATIVE POWER SUPPLY:
Use cable of minimum 2/0 AWG as short as possible, connected to the negative
battery pole.
1 - SMART COOLER:
This amplifier has two internal ventilation fans. For perfect functioning, the amplifier must
be installed in a cool and aired place with at least 1” (25mm) space around the heasink for proper heat spreading.
The usually working temperature of amplifier is 65°C.
In order for your amplifier to have the best performance, it is necessary to use all the power inputs. See example
on the next page. We recommend that all cables have tinned ends for better electrical contact.
10
Power supply connector
LEDS indicators & protection system
The thermal protection waits for cooling before restarting.
If it goes into protection, the amplifier will automatically restart.
Example:
Low Battery Protection:
Working amplifier Red LED (LED Monitor) or Smart LEDS, flashes 2x Red LED
(LED monitor) or Smart LEDS, flashes 2x Amplifier restarts.
Working
amplifier
Battery with voltage
below 9.5V
above 17V
Battery with voltage
Temperature above operating
limit (> 85 ° C)
Led of Monitor
Conditions
Smart LEDs
On - Displays audio
level.
LEDs flashing 2x
LEDs flashing 3x
LEDs flashing
6x per second
Continuously
LEDs flashing
1 second on
1 second off
Blue LED on
Red LED
flashes 2x
Red LED
flashes 3x
Red LED
flashing 6x per
second continuously
Yellow LED
flashing 1 sec. on
1 sec. off
2x
3x
Short circuit on output or
between output terminal to GND
ENGLISH
1
1
2
3
3
2