Technical features
09
Voltage Supply:
127VAC Voltage Range:
220VAC Voltage Range:
Maximum Output Power:
Max. Input Power:
Input Fuse (internal):
Max. Consumption in 220VAC:
Maximum Float at full load (90A @14.2V):
Dimensions(WxHxD):
Average Efficiency:
Output Voltages:
Max. Consumption on 127VAC:
Rated Max. Output Current(*):
Consumption in Stand by (off, but
connected to the outlet):
Weight:
14
90 ~ 140V AC
1300W
Bivolt Automatic (127 / 220VAC)
190 ~ 250V AC
90A
90%
18A
10A
2000VA(***) or
1450W (FP: ~0.60 capacitive)
3W
<2%
20A
12,0V ~ 14.5V (**)
182 x 52 x 256mm (7.17" x 2.05" x 10.1")
1.86Kg (4.09lb)
—
Short Protection:
Temporarily shuts off the output if a short circuit is detected.
—
Thermal protection:
Reduces the output power if the internal temperature rises, automatically returning
to full power as the temperature drops.
Note:
(*) Rated output current, measured with resistive load, source output voltage = 12.6V and mains voltage =
127V / 220V.
(**) Variable voltage depending on the operating mode, and may have values lower than 12V when in slow
charge or thermal protection.
(***) For use with generators, consider the power in VA.