![Taramps Chipeo T9.000 Скачать руководство пользователя страница 12](http://html2.mh-extra.com/html/taramps-0/chipeo-t9-000/chipeo-t9-000_manual_4991922012.webp)
11
Positive / negative power supply cable ___________________
_______________2 x 1/0 AWG
Protection fuse or circuit breaker
____________________________________________450A
Output cables wire gauge_______________________________
_________________7 AWG
Remote cable ___________________
______________________________________ 18 AWG
Calculated considering a maximum length of 4m. Distance greater than this, you will need to
increase the cable gauges.
Installation
Recommended wire gauge & fuse
CAUTION: All connections to power supply, input and output connectors must
be carried out only with amplifier off.
CAUTION
It is compulsory to install a protection fuses or circuit breakers as close as possible from batteries.
Using wire gauges below the recommendation will result in power loss and
overheating of wiring.
Check polarity and never reverse power supply cables due to the risk of damage to the amplifier.
CAUTION
Note:
In case of compression drivers and tweeters you must install a passive filter in the positive
terminal of the same ones (Consult transducer’s manufacturer manual).
*Illustrative Images
Required battery bank capacity: At least 450Ah
50mm² (1/0 A
WG)
50mm² (1/0 A
WG)
12V
GND
GND
12V
DISJUNTOR
10mm² (7 AWG)
10mm² (7 AWG)
Remote Cable 18AWG
Head Unit
This equipment is not
suitable for use in places where children may
be present.
RCA Cable
Taramps
CUIDADO
The entire aluminum surface of
the amplifier acts as a heat sink.
Avoid contact with this surface when the
amplifier is in use.
The normal working temperature is 70°C (158°F).
CUIDADO