State of Delivery
MECps
- 27 -
5.2
Technical Datasheet
Marking/Design
MECps640
Mains voltage
230 V AC ±15 % @ 50 Hz
Leakage loss
(open-circuited)
0.9 W
Leakage loss
(normal operation)
4.4 W
Power consumption
(normal operation)
23.2 W
Power consumption
(max., overload)
39.2 W
Mains failure
bridging time
> 100 ms
KNX output voltage
28…31 V DC (SELV)
Rated current
640 mA
Maximum current
(total output)
1.2 A
Efficiency at nominal load
81 %
Disconnection time after
failure
10 s
Connections
Supply input: Screw terminals,
for 0.3…2.5 mm2 (torque 0.4 Nm)
KNX TP main line: KNX TP connector (red/black), screwless,
for single-
core cable Ø 0.6…0.8 mm
KNX TP subline: KNX TP connector (red/black), screwless,
for single-
core cable Ø 0.6…0.8 mm
LED Display elements
State 1
State 2
Traffic (Main and Sub)
Routing (GA and PA)
Programming LED
Control elements
Function Button
Programming Button
Mounting
35 mm top-hat rail (TH35) according to IEC60715
Protection type
IP20 according to IEC60529
Pollution degree
2 according to IEC60664-1
Protection class
II according to IEC61140
Overvoltage category
III according to IEC60664-1
Approbation
KNX-certified according to ISO/IEC14543-3