6. DATA
IOM manual - Sanitary series
60
We recommend not to exceed the following loads and forces reacting on the manifolds.
T30
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
16,2
3,4
Y
16,2
3,4
Z
16,2
3,4
T80
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
31
6,3
Y
31
6,3
Z
31
6,3
T125
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
35
7,3
Y
35
7,3
Z
35
7,3
T225
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
43
8,8
Y
43
8,8
Z
43
8,8
T425
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
56
11,5
Y
56
11,5
Z
56
11,5
T825
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
93
13,2
Y
93
13,2
Z
93
13,2