3.
MAINTENANCE
IOM manual Tapflo Hose pumps
29
Fig. 3.9.8b PTL30
–
PTL45
If vacuum is not sufficient, remove the front cover
again and add an extra 0.5 mm shim.
Fig. 3.9.9a PTL9
–
PTL25
Repeat steps 3.9.6 and 3.9.7 and check the vacuum.
Move the roller bracket to the next graduation marks
as long as the vacuum reading is (-0.6) bar or lower.
Fig. 3.9.9b PTL30
–
PTL45
Repeat steps 3.9.6 and 3.9.7 and check the vacuum.
Add extra shims as long as the vacuum reading is
(-0.6) bar or lower.
3.9.10a PTL9
–
PTL25
Adjust the loose roller bracket to the same distance,
install the front cover [12] and re-test the pump
vacuum capabilities.
NOTE!
Both rollers need to be adjusted equally.
3.9.10b PTL30
–
PTL45
Add the same number of shims under the second
roller bracket, install the front cover [12] and re-test
the pump vacuum capabilities.
NOTE!
Both rollers need to be shimmed equally.