3. MAINTENANCE
IOM manual Tapflo Metal Series
22
Fig. 3.6.6
Make sure that after screwing in of the valve ball stop
[22] there is no free space between the stopper and
the housing [11].
ATTENTION!
If the valve ball stop is not correctly
screwed in it may break and case damage to the
pump interiors.
Fig. 3.6.7
When fastening the screws, remember to do it
according to the tightening procedure and with the
appropriate torque.
NOTE!
After a few weeks of operation retighten the
screws with the appropriate torque.
3.6.1.
Test run
We recommend you to conduct a test run of the pump before installing it in the system, so
no liquid gets wasted if the pump leaks or perhaps does not start accordingly to wrong
assembly of the pump.
After a few weeks of operation retighten the screws with appropriate torque.
CORRECT
INCORRECT