Explosion hazardous environments
–
ATEX
The standard stainless steel pumps are not allowed to operate in environments where there is
danger of explosion. Static electricity may occur in the pump under operation, which may cause
explosion and injury. Special conductive TX pumps are available for such applications.
All our aluminium and cast iron pumps are by standard ATEX approved, having model names
TX…
Follow below instructions and local/national rules for safe use.
ATEX (directive 2014/34/EU) classification of Tapflo TX pumps:
II
2G
Ex
h
IIC
T6
…
T4
Gb
II
2D
Ex
h
IIIC
T60
º
C
…
T125
º
C
Db
Equipment group:
II
–
all other explosive areas than mines;
Category group:
2
–
high level of protection (can be used in zone 1);
Atmosphere:
G
–
gas;
D
–
dust;
Explosion group:
IIC
–
gas group (such as acetylene, hydrogen);
IIIC
–
dust group (conductive dusts);
Type of protection:
h
–
control of ignition sources;
Temperature class:
T4, T6
–
in the event of a malfunction, the maximum temperature of
a surface that may be exposed to gas
T4
= 135°C
,
T6
= 85
°C
;
EPL protection level:
Gb, Db
–
high protection.
Earth connection of the pump and other equipment
Connect a suitable earth wire to the stainless steel earth connection that is placed on the inside
of one of the pump housings. Connect the other end of the earth wire to earth and also make
sure that other equipment like hoses/pipes/containers etc. are properly earthed/connected.
Dry run in ATEX pump
ATEX approved pumps can run dry without increasing the risk of creating potential ignition
sources. Nevertheless, dry run periods should be decreased to minimum as they increase the
wear of parts inside of the pump. What is more, when running dry (e.g. during self-priming) the
pump should run at a low speed controlled via a needle valve
.
Antistatic surface
Pumps in ATEX execution should be cleaned in order to preserve antistatic properties. Layer of
dust or other solid particles on the outer surfaces is unacceptable.
1.7.3.
Air pressure
The maximum air pressure for Tapflo pumps is 8 bar. Higher air pressure than 8 bar can damage
the pump and may cause injury to personnel in vicinity of the pump. If you intend to apply a
higher air pressure than 8 bar, please consult us.
Содержание Metal Series
Страница 32: ...5 SPARE PARTS IOM manual Tapflo Metal Series 32 5 1 3 TX70 TX420 Spare parts drawing...
Страница 36: ...5 SPARE PARTS IOM manual Tapflo Metal Series 36 5 1 6 TX820 Spare parts drawing...
Страница 38: ...5 SPARE PARTS IOM manual Tapflo Metal Series 38 5 2 Stainless steel pumps 5 2 1 T70 T120 Spare parts drawing...
Страница 40: ...5 SPARE PARTS IOM manual Tapflo Metal Series 40 5 2 3 T220 T420 Spare parts drawing...
Страница 44: ...5 SPARE PARTS IOM manual Tapflo Metal Series 44 5 2 6 T820 Spare parts drawing...
Страница 51: ...6 DATA IOM manual Tapflo Metal Series 51 Dimensions T820 S...
Страница 56: ......