background image

 

IOM Manual – IBC Mixers

 

Mixers - LBC/HBC 

7

  

 

 

 

 

2. Installation and Operation 

2.1. Installation 

 

The mixers  with electric drive are  supplied pre-wired and fitted with a DOL 

starter, overload protection, safety interlock and appliance Inlet Plug.  

The plug colour indicates the power supply required. 

 

Red - indicates a 400v 3ph 50 Hz supply 

 

Blue - indicates a 220-240v 1ph 50 Hz supply 

 

Yellow - indicates a 110v 1ph 50 Hz supply 

The mixers with pneumatic drives are supplied with a flow control valve to regulate the 

motor speed and an exhaust muffler. 

1.

 

Check that the motor / starter voltage requirements correspond with the supply 

or  verify  if  compressed air supply system  is suitable  in case of mixer with air 

motor. 

2.

 

Check that the mixer shaft direction of rotation corresponds to the rotation 

arrow placed on the mixer nameplate - rotation is clockwise when viewed from 

above. 

3.

 

Changes to reverse the direction of rotation must be done by qualified personnel 

only. 

4.

 

Fit the impeller on to the mixer shaft, dimple the shaft on assembly for the set 

screws and tighten securely. 

 

 

5.

 

Fit the mixer shaft into the drive head coupling and tighten the 2  set screws 

(Item 5) through the slot provided in the coupling guard. 

6.

 

Lower the mixer on to the IBC frame with a forklift truck or hoist using the eye 

bolt provided on the mixer.  

 

 

 

 

 

 

Содержание HBC Series

Страница 1: ...IOM Manual IBC Mixers Mixers LBC HBC 3 IBC Mixers Series LBC HBC Edit 2022 IOM manual Read this instruction manual carefully before you install and operate the pump...

Страница 2: ...2 3 Fault Diagnosis 3 Maintenance 3 1 Routine Maintenance 3 2 Lubrication 3 3 Tightening Torques 3 4 Air motor Flushing 3 5 Material Disposal 3 6 Ordering Spare Parts 4 Supplementary Instructions and...

Страница 3: ...IOM Manual IBC Mixers Mixers LBC HBC 3...

Страница 4: ...ler Blank Std Impeller Fixed impeller for HBC folding impeller for LBC E Std Impeller F 280 fixed impeller 280mm diameter F Std Impeller F 300 fixed impeller 300mm diameter G Std Impeller F 320 fixed...

Страница 5: ...ency inverter E External frequency inverter 6 Optional frame connection Blank none H Hopper for powders L Liquid inlet 7 Lifting arrangement Blank Standard lifting frame with eye bolt F Forklift modul...

Страница 6: ...on an IBC and a 16 AMP appliance Inlet plug protection IP44 splash proof The mixer drive is supported on a lightweight stainless steel bridge which mounts directly onto the IBC and is held in place w...

Страница 7: ...or starter voltage requirements correspond with the supply or verify if compressed air supply system is suitable in case of mixer with air motor 2 Check that the mixer shaft direction of rotation corr...

Страница 8: ...mpressed air supply can be connected if safe to do so 9 After use before moving the mixer isolate from the power supply and disconnect the lead to the appliance plug In case of an air motor it should...

Страница 9: ...wrong direction Check that the direction of rotation corresponds with the arrow on the mixer nameplate Rotation is clockwise when viewed from above All drives Impeller rotating in the wrong direction...

Страница 10: ...t higher SG or viscosity product being mixed Contact Tapflo or your local distributor for advice Electric drive Motor starts but has low torque or does not reach full speed 3 phase motor is single pha...

Страница 11: ...ations in the UK BGV A3 in Germany or local site codes of practice as applicable 3 2 Lubrication Electric motor bearings are sealed for life and do not require any maintenance or re lubrication The ge...

Страница 12: ...isposal Tapflo IBC mixers series LBC HBC are designed for a long trouble free life At the end of the useful service life the lubricants and components can be recycled The IBC mixer frame shaft and imp...

Страница 13: ...2 25 Switch plate 1 7 Lifting strap 1 26 Spring operating block 1 8 Lifting eyebolt 1 27 Spring 1 9 Gasket 1 28 Cable gland 6 10 Appliance inlet 1 29 Cable covering 1 11 Hex socket head setscrew 2 30...

Страница 14: ...3 Mounting Frame 1 30 Nameplate 1 4 Drive Coupling 1 32 Hex head screw 2 5 Hexagon socket set screw 4 33 Hexagon nut 2 6 Quick action toggle clamps 2 34 Hex head screw 4 7 Lifting strap 1 35 Hexagon n...

Страница 15: ...equired in the supply line Adjust the air line lubricator to 1 drop of oil per minute Regulate the line pressure to 7 bar max Noise air motors are supplied with the standard muffler on the exhaust air...

Страница 16: ...level radial flow fixed impeller can also be supplied for mixing the IBC contents at very low liquid levels install below the folding impeller as illustrated A 1000mm long shaft is available with thi...

Страница 17: ...e needs of the Customer except for those purposes set out in any invitation to render documents or other documents specifically made available to Tapflo before entering into this agreement c high qual...

Страница 18: ...nt under the terms of this warranty shall not give a right to an extension to or a new commencement of the period of warranty 6 Repair or replacement under the terms of this warranty shall not give a...

Страница 19: ...IOM Manual IBC Mixers IBC Mixers LBC HBC 19...

Отзывы: