background image

 

IOM Manual – IBC Mixers

 

Mixers - LBC/HBC 

 

 

 

 

1.3. Inspection 

 

On receiving delivery of your IBC Mixer please inspect carefully to confirm that 

your mixer has been received un-damaged and to the correct specification. Report any 

shortages or damage immediately in writing to the carrier or supplier. Contact details 

can be found at the back of this manual. 

 

1.4. Storage 

 

IBC Mixers series LBC, HBC should be stored in an indoor, clean, dry location 

with a controlled temperature of 15°C to 40°C until the mixer is ready to be used. 

 

1.5. Description 

Tapflo IBC Mixers series LBC, HBC  are designed for use on Industry standard 

Intermediate Bulk Containers (IBC) with a 150mm screw cap and are suitable for most 

container types.  

The IBC mixers are for use indoors in a safe area only and is fitted with a DOL 

starter with overload protection and a safety switch

 to prevent the mixer operating if the 

mixer is not securely mounted on an IBC and a 16 AMP appliance Inlet plug protection 

IP44 - splash proof.  

 

The mixer drive is supported on a lightweight stainless steel bridge which 

mounts directly onto the IBC and is held in place with quick action toggle clamps, 

standard lifting is an eye bolt for lifting with a hoist or optional fork lift module. 

 

1.6. Safety 

The following instructions are important.  

• Observe all site safety procedures installing and operating your IBC mixer 

• Familiarize yourself with the material being mixed in the IBC and obtain product safety 

data sheets, protective clothing and appropriate eye protection before proceeding. 

• Use lifting equipment i.e. fork lift or hoist to install the mixer onto an IBC mixer. Mass 

in Kg is indicated on the mixer nameplate. 

• Mount the mixer securely onto the IBC complete with shaft and impeller before 

connecting to the power supply. 

• Disconnect from the power supply before moving the mixer or carrying out 

maintenance. 

• Do not touch any moving / rotating parts. 

• Do not touch the motor after use - Hot Surface 

 

WARNING – failure to observe safety instructions could cause severe personal injury. 

Содержание HBC Series

Страница 1: ...IOM Manual IBC Mixers Mixers LBC HBC 3 IBC Mixers Series LBC HBC Edit 2022 IOM manual Read this instruction manual carefully before you install and operate the pump...

Страница 2: ...2 3 Fault Diagnosis 3 Maintenance 3 1 Routine Maintenance 3 2 Lubrication 3 3 Tightening Torques 3 4 Air motor Flushing 3 5 Material Disposal 3 6 Ordering Spare Parts 4 Supplementary Instructions and...

Страница 3: ...IOM Manual IBC Mixers Mixers LBC HBC 3...

Страница 4: ...ler Blank Std Impeller Fixed impeller for HBC folding impeller for LBC E Std Impeller F 280 fixed impeller 280mm diameter F Std Impeller F 300 fixed impeller 300mm diameter G Std Impeller F 320 fixed...

Страница 5: ...ency inverter E External frequency inverter 6 Optional frame connection Blank none H Hopper for powders L Liquid inlet 7 Lifting arrangement Blank Standard lifting frame with eye bolt F Forklift modul...

Страница 6: ...on an IBC and a 16 AMP appliance Inlet plug protection IP44 splash proof The mixer drive is supported on a lightweight stainless steel bridge which mounts directly onto the IBC and is held in place w...

Страница 7: ...or starter voltage requirements correspond with the supply or verify if compressed air supply system is suitable in case of mixer with air motor 2 Check that the mixer shaft direction of rotation corr...

Страница 8: ...mpressed air supply can be connected if safe to do so 9 After use before moving the mixer isolate from the power supply and disconnect the lead to the appliance plug In case of an air motor it should...

Страница 9: ...wrong direction Check that the direction of rotation corresponds with the arrow on the mixer nameplate Rotation is clockwise when viewed from above All drives Impeller rotating in the wrong direction...

Страница 10: ...t higher SG or viscosity product being mixed Contact Tapflo or your local distributor for advice Electric drive Motor starts but has low torque or does not reach full speed 3 phase motor is single pha...

Страница 11: ...ations in the UK BGV A3 in Germany or local site codes of practice as applicable 3 2 Lubrication Electric motor bearings are sealed for life and do not require any maintenance or re lubrication The ge...

Страница 12: ...isposal Tapflo IBC mixers series LBC HBC are designed for a long trouble free life At the end of the useful service life the lubricants and components can be recycled The IBC mixer frame shaft and imp...

Страница 13: ...2 25 Switch plate 1 7 Lifting strap 1 26 Spring operating block 1 8 Lifting eyebolt 1 27 Spring 1 9 Gasket 1 28 Cable gland 6 10 Appliance inlet 1 29 Cable covering 1 11 Hex socket head setscrew 2 30...

Страница 14: ...3 Mounting Frame 1 30 Nameplate 1 4 Drive Coupling 1 32 Hex head screw 2 5 Hexagon socket set screw 4 33 Hexagon nut 2 6 Quick action toggle clamps 2 34 Hex head screw 4 7 Lifting strap 1 35 Hexagon n...

Страница 15: ...equired in the supply line Adjust the air line lubricator to 1 drop of oil per minute Regulate the line pressure to 7 bar max Noise air motors are supplied with the standard muffler on the exhaust air...

Страница 16: ...level radial flow fixed impeller can also be supplied for mixing the IBC contents at very low liquid levels install below the folding impeller as illustrated A 1000mm long shaft is available with thi...

Страница 17: ...e needs of the Customer except for those purposes set out in any invitation to render documents or other documents specifically made available to Tapflo before entering into this agreement c high qual...

Страница 18: ...nt under the terms of this warranty shall not give a right to an extension to or a new commencement of the period of warranty 6 Repair or replacement under the terms of this warranty shall not give a...

Страница 19: ...IOM Manual IBC Mixers IBC Mixers LBC HBC 19...

Отзывы: