background image

  

Instruction manual CT centrifugal pumps 

25 

6. 

WARRANTY

6.1 

Returning parts

When returning parts to Tapflo please follow this procedure:

-   Consult Tapflo for shipping instructions.

-   Cleanse or neutralize and rinse the part/pump. Make sure the part/pump is completely empty from 

liquid.

-   Pack the return articles carefully to prevent any damage under transport.

Goods will not be accepted unless the above procedure has been complied with.

6.2 

Warranty

Tapflo warrants products under conditions as below for a period of not more than 12 months from instal-
lation and not more than 24 months from date of manufacture.

1.  The following terms and condition apply to the sale of machinery, components and related services 

and products, of Tapflo  (hereinafter “the products”)

2.  Tapflo (the manufacturer) warrants that:

a.)  its products as being free of defects in material, design and workmanship at the time of original 

purchase;

b.)  its products will function in accordance with Tapflo operative manuals; Tapflo does not guarantee 

that the product will meet the precise needs of the Customer, except for those purposes set out  in 
any invitation to render documents or other documents specifically made available to Tapflo before 
entering into this agreement;

c.)  high quality materials are used in the construction of the pumps and that machining and assembly 

are carried out to the highest standards.

Except as expressly stated above, Tapflo makes no warranties, express or implied, concerning the pro-
ducts, including all warranties of fitness for a particular purpose.

3.  This warranty shall not be applicable in circumstances other than defects in material, design, and 

workmanship. In particular warranty shall not cover the following:

a.)  Periodic checks, maintenance, repair and replacement of parts due to normal wear and tear (seals, 

O-rings, rubber items, bushings, etc..);

b.)  Damage to the product resulting from:
b.1.) Tampering with, abuse or misuse, including but not limited to failure to use the product for its 

normal purposes as stated at the time of purchase or in accordance withTapflo instructions for use 
and maintenance of the product, or the installation or improper ventilation or use of the product 
in a manner inconsistent with the technical or safety standard in force;

b.2.) Repairs performed by non skilled personell or use of non original Tapflo parts
 
b.3.) Accidents or any cause beyond the control of Tapflo, including but not limited to lightning, water, 

fire, earthquake, and public disturbances, etc.;

The warrantee shall cover the replacement or repairing of any parts, which is documentedly faulty 

due to construction or assembling, with new or repaired parts free of charges delivered by Tapflo. 
Parts subjected to normal tear and wear shall not be covered by the warranty.  Tapflo shall decide 
as to whether the defective or faulty part shall be replaced or repaired.

The warrantee of the products shall be valid for a period in accordance to the current law from 

the date of delivery, under the condition that notice of the alleged defect to the products or parts 
thereof be given to Tapflo in written within the mandatory term of 8 days  from the discovery.

Changes reserved without notice

Содержание CTI AA-03

Страница 1: ...0 m3 h 32 m With motor 1450 rpm CTI AA 024 7 m3 h 2 7 m CTI BB 054 9 m3 h 2 8 m CTI CC 114 18 m3 h 5 5 m CTI CE 114 22 m3 h 7 7 m CTI DD 224 25 m3 h 5 5 m CTI DF 224 34 m3 h 8 7 m CTI DG 224 42 m3 h 1...

Страница 2: ...rocedure 10 3 Maintenance 11 3 1 Inspections 11 3 2 Location of faults 11 3 3 Assembly and disassembly 12 3 3 1 Pump casing assembly and disassembly 12 3 3 2 Impeller and back casing disassembly 13 3...

Страница 3: ...odels CT Is in conformity with the essential health and safety requirements and technical con struction file requirements of the EC Machinery directive 2006 42 EC with amendments 91 368 EEC 93 94 EEC...

Страница 4: ...nd limb may occur Observe these instructions and proceed with utmost caution in these situations Inform also other users of all safety instructions In addition to the in structions in this instruction...

Страница 5: ...tly necessary to start the pump Temperature hazards The cold or hot parts of the machine must be protected to avoid accidental contacts Rotating parts Do not tamper with the protection of the rotating...

Страница 6: ...eat influence on operation and the operating life of the pump The pump can not be used as a support for the components connected to it The flow of liquid from the pump must be as even as possible It i...

Страница 7: ...w joints and other parts on the pump discharge and suction lines 12 With negative suction lift tilt of piping towards suction tank 13 YES check valve with negative suction lift 14 YES strainer if part...

Страница 8: ...umps such as valves closed accidentally missing liquid overloads etc Thermometer If the temperature of the pumped liquid can be a critical element provide a thermometer preferably on suction 1 7 Motor...

Страница 9: ...1 1 Starting the pump Start the electric motor and open the discharge adjustment shutoff valve gradually until the desired output has been reached The pump must not turn more than two or three minutes...

Страница 10: ...the CIP procedure Make sure that all cleaning line connections are properly tightened to avoid splashing of hot water or cleaning chemicals When using a automatic process a safety device should be in...

Страница 11: ...e diameter of the suction pipe Make suction pipe short and direct Pump is clogged Clean the pump Cavitation Increase suction pressure The pump sucks air Make sure all connections on suction pipe are t...

Страница 12: ...or the environment STOP 11 121 Fig 3 3 Assembly drawing for CT pumps 1 122 90 13 16 18 161 192 143 191 141 142 12 17 15B 15A Fig 3 Assembly drawing for CT pumps Fig 4 Fig 5 3 3 1 Pump casing 13 assemb...

Страница 13: ...in the back casing Fig 8 Fig 6 Fig 9 Fig 7 Fig 10 Fig 8 Fig 11 3 3 3 Mechanical seal 15 assembly and disassembly Follow the disassembly instructions for the pump casing 3 3 1 and impeller and back ca...

Страница 14: ...e disassembled the motor shaft extension In order to adjust the dimension S move the shaft extension 16 Carefully slide the rotating part of the seal 15A onto the shaft extension 16 Fig 14 Mount the i...

Страница 15: ...M6 15 5 M6 15 5 M6 15 6 M8 15 6 M8 Pos 141 allen screw Mounting torque Nm Tool size s mm Thread 15 5 M6 15 6 M8 15 8 M10 15 6 M10 15 6 M8 Pos 143 hexagonal nut Mounting torque Nm Tool size s mm Threa...

Страница 16: ...mechanical seal NBR lip seal is a standard other materials are available upon request Oil chamber should be filled up to of oil cup height You should change oil after 2000 hours of operation or once a...

Страница 17: ...jacket 120 Pump back casing with heating jacket 125 Joint for pump with heating jacket Comparing to standard execution heating jacket option contains followed additional parts 3 7 Flushed seal When a...

Страница 18: ...Plug for pump with welded seal chamber 159 Lip seal for 4Z pump congiguration 16Z Shaft for pump with lubricated seal 62 Oil reservoir for seal Pos Description 11146 Pump back cover for flushed and o...

Страница 19: ...rain plug o ring 3 10 Long coupled execution Long coupled execution is a perfect solution when pumping hot products like oil at temperatures up to 180 C Complete pump unit is mounted on baseplate with...

Страница 20: ...8 8 8 AISI 316L AISI 316L 143 Casing mounting nuts 4 4 4 8 8 8 AISI 316L AISI 316L 15 Mechanical seal complete H N 1 1 1 1 1 1 See 4 4 See 4 4 16 Shaft extension 1 1 1 1 1 1 AISI 316L AISI 316L 161 Lo...

Страница 21: ...2 304 140 216 256 CTI AA 024 0 25 71 60 358 36 100 71 193 90 112 145 CTI BB 054 0 55 80 63 395 50 110 80 205 100 125 170 CTI CC 114 1 1 90 64 451 68 160 90 226 125 140 205 CTI CE 114 1 1 90 64 451 68...

Страница 22: ...7 5 132 70 587 92 192 132 304 140 216 256 CTH AA 024 0 25 71 60 358 36 100 71 197 90 112 145 CTH BB 054 0 55 80 63 395 50 110 80 205 100 125 170 CTH CC 114 1 1 90 64 451 68 160 90 226 125 140 205 CTH...

Страница 23: ...EPDM FDA on CTH 1SSV SiC SiC FKM CTI only 1SSF SiC SiC FEP FDA 1SSN SiC SiC NBR CTI only 1SGE SiC graphite EPDM FDA on CTH 1SGV SiC graphite FKM CTI only 1SGF SiC graphite FEP FDA 1SGN SiC graphite N...

Страница 24: ...Performance curves The performance curves are based on water at 20 C Contact us for detailed curves CTDG CTEG CTDF CTAA CTBB CTCC CTCE CTEF CTDD CTDF CTEF CTAA CTBB CTCC CTDD CTDF CTDG CTCE Speed 290...

Страница 25: ...ding all warranties of fitness for a particular purpose 3 This warranty shall not be applicable in circumstances other than defects in material design and workmanship In particular warranty shall not...

Страница 26: ...lly designed and manufactured This warranty shall not reimburse such adaptations changes or adjustments or attempt to do so whether properly performed or not nor any damage resulting from them nor any...

Страница 27: ...Pump type Serial No see name plate Description of the fault The installation Liquid Temperature C Viscosity cPs Spec grav kg m3 pH value Contents of particles of max size mm Flow l min Duty h day No...

Отзывы: