background image

Release 08/2007 Ver. 2.0 

 

Technical Manual: C6 Multifunction Interface Controller

  

TAPESWITCH CORPORATION

 

 

Phone: 631-630-0442 

100 Schmitt Boulevard 

7

 

Fax: 631-630-0454 

Farmingdale, New York 1735 

 

www.tapeswitch.com 

MAT 1

MAT 2

MAT 3

MAT N

YELLOW

W HITE

BLACK

RED

YELLOW

YELLOW

YELLOW

RED

RED

RED

W HITE

W HITE

W HITE

BLACK

BLACK

BLACK

C

D
B

A

MAT 1

MAT 2

MAT 3

MAT N

W HITE #2

BLACK #2

BLACK #1

W HITE #1

C

D
B

A

BLACK

W HITE

W HITE

BLACK

BLACK

W HITE

W HITE

BLACK

BLACK

W HITE

W HITE

BLACK

Edge/sensor 1

W HITE #1

BLACK #1

W HT

BLK

C

D
B

A

W HITE

W HITE #2

BLACK

BLACK #2

W HT

W HT

W HT

BLK

BLK

BLK

Edge/sensor 2

Edge/sensor N

SM O O TH #1

RIBBED #1

SM O

RIB

C

D

B

A

SM O O TH

SM O OTH #2

RIBBED

RIBBED #2

SM O

SM O

SM O

RIB

RIB

RIB

Edge/sensor 1

Edge/sensor N

Edge/sensor 2

INTERCO NNECT DIAG RAM S, DAISY CHAINED/SERIES CO NNECTIO N

M ultiple M ats w ith 4 Conductor Standard Color Coded Lead W ire

NOTE:  M axim um Num ber of M ats Lim ited to 100 Square Feet

M ultiple M ats w ith O ptional 2 Conductor Standard Color Coded Lead W ire

M ultiple Sensing Edges, Bum pers and Ribbon Sw itches w ith Color Coded W ire

Edges and Bum pers Can Be Ordered with Lead W ire Exiting Both Ends to Facilitate Easy Series Connection

NOTE:  M axim um  Num ber of Edges, Bum pers, and Ribbon Switches Lim ited to 200 Feet

M ultiple Sensing Edges, Bum pers and Ribbon Sw itches w ith Non-Color Coded Zip Cord W ire

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 6 - Multiple Sensor Connections

 

 

Содержание C6

Страница 1: ...they are correctly fitted to a suitable machine It is essential that the full contents of this manual and all the international documents referred to herein are fully understood before any attempt at...

Страница 2: ...ork 1735 www tapeswitch com CONTENTS Page 1 INTRODUCTION 3 2 METHODS OF INTERFACING 3 3 ELECTRICAL CONNECTIONS 4 3 1 Reset Manual Automatic 3 2 Pressure Sensitive Sensor s Connections 3 3 Mechanical 3...

Страница 3: ...two closed contacts will open when the sensing device is actuated i e safety mat is stepped on or should a fault occur within the safety device or in the event that the power is removed The outputs wi...

Страница 4: ...e g as an input to a PLC To protect the contacts of the safety output relays from the effects of switching inductive loads an appropriately rated power factor correction device must be installed for t...

Страница 5: ...on Wiring Diagram taking particular care that there are no stray strands which could cause a short between the adjacent terminals A number of sensors can be connected in series See Figure 6 for detail...

Страница 6: ...O N C N O CTR N C N O CTR N C CTR N O N C N O CTR N C N O Safety O P 1 Safety O P 2 Monitor O P 1 Monitor O P 2 Monitor O P 3 Monitor O P 4 Monitor O P 5 Monitor O P 6 M AT 1 GUARD 1 MAT 2 M AT 3 MAT...

Страница 7: ...ensor 2 Edge sensor N SMOOTH 1 RIBBED 1 SMO RIB C D B A SMOOTH SMOOTH 2 RIBBED RIBBED 2 SMO SMO SMO RIB RIB RIB Edge sensor 1 Edge sensor N Edge sensor 2 INTERCONNECT DIAGRAMS DAISY CHAINED SERIES CON...

Страница 8: ...Controller Safety Outputs to Machine Controls Power Input Zone 6 Zone 5 Zone 4 Zone 2 or Sensor 1 Emitter 1 Receiver 1 W1 W2 Zone 1 Sensor 2 or Receiver 2 Emitter 2 W2A W1A Zone 3 Sensor 3 or Emitter...

Страница 9: ...W 2 Gray Output 2 5 G1B W 2 Pink Data 6 Isolate 6 7 No Connection W 2 Blue Data 7 Isolate 6 7 No Connection W 2 Shield Ground 8 COM Cable Cable Type Color Code Function From Light Curtain 2 C6 to Guar...

Страница 10: ...V DC 2 COM W 1 B Blue Test Out TWIST PAIR TOGETHER Black Blue Wire No Connection W 1 B Black Test In No Connection W 1 B Gray Ground 5 COM RKT8 09 XX Receiver 8 Pin Quick Disconnect W 2 B White OV DC...

Страница 11: ...even if the sensors and or light curtain is cleared until the key switch reset is applied 4 Once the reset is applied the flashing red light s for the activated zone s will turn off and the six green...

Страница 12: ...C Power Consumption 30VA TYPICAL Enclosure Type Metal Wall Mount Protection Rating NEMA 1 Standard IP10 NEMA 12 Optional IP52 Weight 9 5 lbs 4 3 kg Sensor Wiring Fail Safe Reset Mode Automatic supplie...

Страница 13: ...100 Schmitt Blvd Farmingdale NY 11735 Toll Free 1 800 234 8273 Tapeswitch CORPORATION MANUAL MODE OUTPUT OFF OUTPUT ON C 6 M U L T IF U N C T IO N C O N T R O L E R C6 Multifunction Controller C6 10M...

Отзывы: