Tannoy VLS SERIES Скачать руководство пользователя страница 7

5. Wiring and connections

VLS Series Operation Manual  rev 1.0.0

7

    

superior to a lower power amplifier running at 100%. An amplifier with insufficient drive capability will not 
allow the full performance or the loudspeaker to be realised. (See technical specifications section for 
recommended amplifier power.) 

When using amplifiers from different manufacturers in a single installation, make certain that all amplifiers have 
closely matched gains. (Variation should be less than +/- 0.5 dB.) This precaution is important to the overall 
system balance when only a single active crossover is being used with multiple cabinets. When possible, it is 
recommended that the same amplifiers be used throughout.

Series/parallel connections

 - When running low-impedance loudspeakers in parallel, care must be 

taken not to allow the impedance to drop too low, as damage may be sustained by the amplifier. Most low 
impedance amplifiers will be able to handle loads of 2 ohms to 8 ohms. This means for example that when 
using an amplifier with 2 ohm load rating, up to three VLS 30 or six VLS 7/15 may be connected in parallel 
per output, although care should be taken as impedance varies with frequency and at some frequencies the 
impedance will drop to below 2 ohms.

5.3 Constant voltage (70 /100 V) Mode 

In constant voltage distributed systems, normally a number of loudspeakers are connected in parallel to a single 
amplifier output. Connect the positive (+) conductor from the amplifier or prior loudspeaker in the system to a 
positive (+) barrier strip terminal and the negative (-) conductor to a negative (-) terminal. The other parallel 
barrier strip is available for connecting additional loudspeakers.

A multi-position rotary switch on the rear input panel selects either the low-impedance operating mode or the 
high-impedance modes (70 V or 100 V) with available transformer taps. When using VLS Series loudspeakers in 
distributed line systems, the transformer can be tapped with available power levels shown in the table below: 

70 V

100 V

5 W

9.5 W

9.5 W

19 W

19 W

37.5 W

37.5 W

75 W

75 W

150 W

150 W

-

Содержание VLS SERIES

Страница 1: ...Operation Manual VLSSERIES Professionalloudspeakers Operation Manual...

Страница 2: ...ted dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is inten...

Страница 3: ...ode 6 5 3 Constant voltage 70 100 V mode 7 5 4 Wiring for outdoor applications 8 6 Polarity checking 8 7 Equalisation 9 8 Mounting and flying 9 8 1 Asymmetrical pattern considerations 9 8 2 Mounting a...

Страница 4: ...concourses Easy mounting is facilitated via supplied wall and flying brackets with an optional pan tilt bracket available Aided by an addition of an exclusive Tannoy edition of EASE Focus v2 0 softwa...

Страница 5: ...wider frequency and dynamic range However if the cable runs are excessively long then the sound quality may be compromised due to the increase in cable resistance and the resulting power losses To ke...

Страница 6: ...re size should be increased Please refer to the following table for guidance Cable Run m C S A of each conductor mm2 AWG Cable resistance ohms Power loss into 4 ohm load dB loss into 4 ohm load Power...

Страница 7: ...oads of 2 ohms to 8 ohms This means for example that when using an amplifier with 2 ohm load rating up to three VLS 30 or six VLS 7 15 may be connected in parallel per output although care should be t...

Страница 8: ...efore the speaker system is mounted or flown will help ensure satisfactory performance If you do not have a pulse based polarity checker you may check LF units as follows Connect two wires to the and...

Страница 9: ...erage area due to constructive and destructive interference effects between the two sources Comb filtering cannot be cured by equalisation this should be addressed with proper loudspeaker placement 8...

Страница 10: ...and washers as shown The other part is secured to the wall The bar on the bottom of the speaker plate slides into the bottom notch of the wall plate while the top is secured with the two supplied scre...

Страница 11: ...other Tannoy professional products or any other devices Using Tannoy professional hardware for any purpose other than that indicated in this guide is considered to be improper use Such use can be very...

Страница 12: ...dust and moisture ingress and are resistant to both salt spray and UV exposure making them suitable for use in most outdoor applications Please consult with your Tannoy dealer before installation in a...

Страница 13: ...Construction Enclosure Aluminium extrusion Aluminium extrusion Aluminium extrusion Finish Ral 9003 white Ral 9003 white Ral 9003 white Ral 9004 black Ral 9004 black Ral 9004 black Custom RAL finishes...

Страница 14: ...be carried out by a Tannoy Professional dealer or service agent This warranty in no way affects your statutory rights For further information please contact your dealer or distributor in your country...

Страница 15: ...igned and constructed such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended and the apparatus...

Страница 16: ...00 971 04 4401208 E enquiries tannoy com Tannoy operates a policy of continuous research and development The introduction of new materials or manufacturing methods will always equal or exceed the publ...

Отзывы: