Tannoy SYSTEM 600a Скачать руководство пользователя страница 8

SERVICING

Cabinet finish.

To remove marks and scuffs, use a medium soft brush. If necessary, a little warm water
and detergent can be used, but under no circumstances use a solvent or abrasive
cleaner. The surface will change colour when wet but will return to normal when dry. For
touch-up of paint chips contact your local Tannoy service agent for materials and
guidance.

Dual Concentric driver removal.

Before any servicing operation the amplifier should be disconnected from signal input
and mains power.
Lay the cabinet on its back taking care to protect the rear plate. Remove the four
hexagonal bolts and set aside. Ease the driver from the front of the cabinet taking care
not to mark the front surface.
Use a piece of stout cardboard to lever against if necessary. Remove the driver and
disconnect the internal wiring, taking care not to damage the moving parts of the LF
driver.
To refit the driver, connect the cables from the wiring harness to the LF (brown and blue
leads) and HF (yellow and green) terminals. Fit the driver into mounting hole, fasten the
bolts finger tight and then progressively torque them down so that the driver seats
evenly.

Drive unit servicing.

The HF unit may be fitted with a new diaphragm assembly. With the driver face down,
release the three bolts securing the HF assembly and lift the HF unit vertically upwards
and away from magnetic attraction caused by the LF magnet. Replace the diaphragm -
it is self-centring - taking care to align the parts correctly.

To refit the HF unit, hold it about 300 mm vertically above the LF magnet in both hands
while resting on your elbows. Slide your elbows apart and lower the HF unit onto the
back of the LF magnet. As the HF unit gets close to the magnet you will feel the
magnetic fields repelling. Align the fixing holes and secure with the bolts, tightening
down evenly. Do not tighten the bolts finally until you are sure the HF unit is seated
correctly and the two magnet systems appear parallel.

The LF unit may be re-coned in the normal way. Use only the parts and adhesive
supplied in the re-cone kit.

Checking the unit.

The whole unit can be checked using a sine wave generator connected to the input. A
high quality, low distortion (preferably a beat frequency) oscillator will be required to
check for any buzz and rattle noise generated by the drive unit. The voltage to be
applied at the input should be 0.2 Vrms for input level switch set to +4 dBu. Testing the
whole unit has an obvious drawback in that, in the case of any defect it may be difficult
to determine whether the drive unit or the amplifier is faulty. In which case each part
would have to be checked independently, meaning that the drive unit should be
removed (refer to above).

If for whatever reason the amplifier needs to be removed from the cabinet, care should
be taken to remove only the relevant screws (there are 8 mounting screws, 2 on each
side of the plate).

Содержание SYSTEM 600a

Страница 1: ...System 600a USER MANUAL...

Страница 2: ...e to TV screens and video monitors 3 SYSTEM DESCRIPTION AND PHILOSOPHY 4 Drive unit 4 Cabinet 4 Active crossover and amplifier 5 SERVICING Cabinet finish 6 Dual Concentric driver removal 6 Drive unit...

Страница 3: ...eaker out carefully Inspect the speakers for signs of transit damage In the unlikely event of this having occurred inform the carrier and the supplier Keep all the packaging if damage has occurred as...

Страница 4: ...ure the direct sound radiation from the Dual Concentric drive unit when sitting down The engineer and producer should have a clear uninterrupted view of the monitor loudspeakers Having chosen an appro...

Страница 5: ...cursion is maintained within safe operating limits Also the boost applied to the signal in the Free space position will reduce the headroom on the LF amplifier channel and therefore the maximum SPL av...

Страница 6: ...copper wire chemically bonded onto a kapton former fitting onto the outside of the HF diaphragm skirt The thermal power handling of the voice coil is greatly increased thanks to its ferrofluid filled...

Страница 7: ...s been designed using a dedicated computer simulation program The result is an unconventional topology giving optimum electronic transfer functions i e achieving the desired target response when combi...

Страница 8: ...y from magnetic attraction caused by the LF magnet Replace the diaphragm it is self centring taking care to align the parts correctly To refit the HF unit hold it about 300 mm vertically above the LF...

Страница 9: ...countersunk black 6184 0042 Port tube 6481 0280 System 600A User manual 6730 0333 Carton kit System 600A 6460 0066 Moulded badge label 7300 0565 System 600A amplifier complete unit 7900 0476 System 60...

Страница 10: ...CURVES Figure 3 System 600A Anechoic response LF contour ON OFF Figure 4 System 600A Effect of HF contour on anechoic response...

Страница 11: ...220 240V or 110 120V Fuse T1A 250V 220 240V range or T2A 250V 110 120V range Power consumption 10 to 220 VA Cabinet Drive unit 6 5 Tannoy Dual Concentric type 1678 Low frequency design Bass reflex loa...

Страница 12: ...o electromagnetic disturbance to enable operation as specified and intended The apparatus complies with the Principal Elements of the Safety Objectives of the Low Voltage Directive 73 23 EEC Details o...

Отзывы: