INTRODUCTION

Thank you for purchasing the Tannoy System 600A Active Monitor.

The System 600A is a very compact, active near-field reference monitor. Using an
advanced Dual Concentric 6.5” driver, it offers the advantages of point source operation
in a cost-effective design, combined with the benefits of active speaker technology: a
highly optimised active crossover section; ideal matching between amplifiers and
transducers; higher output for lower distortion. Active user controls are also provided to
allow further bass extension (LF contour) and greater flexibility. The attractive octagonal
shape of the cabinet, with its original rounded edge front panel also contributes to the
excellent acoustic performance of the system.

Designed to be located on top of the mixing console, in a landscape format, it will
equally suit other situations where it can be used in portrait mode without any drawback,
thanks to its point source operation.

This manual is intended to provide the user with some useful advice on how to install
and use the loudspeakers, as well as more technical information about how the system
is designed, and its detailed specifications. Our goal is to help you get the best results
from this monitoring system.

OPERATING INSTRUCTIONS

Unpacking and visual checks

The System 600A are packed in pairs. To get the speakers out of the carton without
damage open the end flaps fully and bend them right back . Remove the upper cushion,
then lift each loudspeaker out carefully.

Inspect the speakers for signs of transit damage. In the unlikely event of this having
occurred inform the carrier and the supplier. Keep all the packaging if damage has
occurred as this will show evidence of any excessive handling forces. It is also a good
idea to keep the carton for future transportation.

Preliminary recommendation

Initially we would like to give you a word of warning about the high sound pressure
levels which these speakers are capable of generating. Over a sustained period of time
levels over 95 dB for 8 hours per day will eventually cause permanent hearing loss.
Because Tannoy monitors have very low levels of time, amplitude and frequency
distortion it is not always obvious that the sound pressure level is high whilst working
with them.

For continuous exposure we recommend the occasional use of a sound level meter
capable of integrating the sound level over a period of exposure according to noise
control standards. This should be used just to check that noise levels are always within
safe limits.

Installing and connecting the system.

The compact, integrated design of  a self-powered unit like the System 600A makes it
particularly easy to install.

After having unpacked the unit, first check that the operating voltage is properly set
(rear panel, location 1 in figure 1), and if it is not adjust the selector to the appropriate
position. Also check and if necessary replace the fuse (location 3), as its rating should
match the operating voltage.

When choosing a suitable location for the monitors, bear in mind that the physical
mounting of loudspeakers can have a large influence on performance. For best results

Содержание SYSTEM 600a

Страница 1: ...System 600a USER MANUAL...

Страница 2: ...e to TV screens and video monitors 3 SYSTEM DESCRIPTION AND PHILOSOPHY 4 Drive unit 4 Cabinet 4 Active crossover and amplifier 5 SERVICING Cabinet finish 6 Dual Concentric driver removal 6 Drive unit...

Страница 3: ...eaker out carefully Inspect the speakers for signs of transit damage In the unlikely event of this having occurred inform the carrier and the supplier Keep all the packaging if damage has occurred as...

Страница 4: ...ure the direct sound radiation from the Dual Concentric drive unit when sitting down The engineer and producer should have a clear uninterrupted view of the monitor loudspeakers Having chosen an appro...

Страница 5: ...cursion is maintained within safe operating limits Also the boost applied to the signal in the Free space position will reduce the headroom on the LF amplifier channel and therefore the maximum SPL av...

Страница 6: ...copper wire chemically bonded onto a kapton former fitting onto the outside of the HF diaphragm skirt The thermal power handling of the voice coil is greatly increased thanks to its ferrofluid filled...

Страница 7: ...s been designed using a dedicated computer simulation program The result is an unconventional topology giving optimum electronic transfer functions i e achieving the desired target response when combi...

Страница 8: ...y from magnetic attraction caused by the LF magnet Replace the diaphragm it is self centring taking care to align the parts correctly To refit the HF unit hold it about 300 mm vertically above the LF...

Страница 9: ...countersunk black 6184 0042 Port tube 6481 0280 System 600A User manual 6730 0333 Carton kit System 600A 6460 0066 Moulded badge label 7300 0565 System 600A amplifier complete unit 7900 0476 System 60...