Introduction

Thank you for purchasing Tannoy i5 MP.

The Tannoy i5 MP is a powered loudspeaker and has been designed to be both
sonically and cosmetically pleasing for a range of applications from AV presentations
to public address.

ICT

TM

or Inductive Coupling Technology offers point source operation, and can h ence

be used in both landscape and vertical positions without affecting the sound quality.
The ICT™ utilises a wireless electromagnetic tweeter that does not require a
crossover and cannot be burned out from heavy or abusive use. The 1" aluminium
high frequency dome has a deep drawn skirt which sits inside the low frequency voice
coil in the same magnetic gap. The skirt is like a single shorted turn, which is induced
with high frequency information generated by the low frequency voice coil, which is
fed a full bandwidth signal. The ICT

TM

dome is at the heart of our i5 MP transducer

which utilises a moulded plastic cone and nitryl rubber surround to further enhance
its' durability and long term reliability.

The ICT

TM

driver is housed in a plastic enclosure that has been optimally tuned to

achieve maximum bass response and tonal balance.

For applications requiring extended low frequency enhancement, a range of Tannoy
sub - bass systems are available and can be used in conjunction with the i5 MP.

2. Unpacking

Every Tannoy i5 MP is carefully tested and inspected before packing. After
unpacking, please inspect your i5 MP for any damage sustained during transit. In the
unlikely event of any damage, would you please notify your dealer immediately and
retain your shipping carton, as your dealer may ask you to return the faulty unit for
inspection.

3. Power Requirements

After unpacking check that the voltage rating is correct. The selector can be found
on the rear panel at the back of the speaker, Figure 3a. If the voltage is incorrect,
move the voltage selector to the appropriate voltage. Check that the panel mounted
fuse is also correct for the correct operating voltage , which is located on the same
panel, and can be removed by unscrewing it from the panel. The fuse rating should
match the operating voltage: 500mA/250V for 220

- 240V operation and 1A/125V for

100- 120V operation. The fuse is 5mm ´ 20mm Time Delay, low rupture type. The
fuse should, however, correspond to the set voltage when shipped.

Figure 3a

Fuse Holder

Voltage

Selector

Содержание i5 MP

Страница 1: ...i5 MP USER MANUAL ...

Страница 2: ...onnectors Cabling 4 4 2 Powering 4 4 3 Controls 5 5 Operation close to TV screens and video monitors 5 6 Equalisation 5 7 Dimensions 5 8 Hardware 6 9 Performance Data 7 10 Technical Specifications 9 11 IMPORTANT SAFETY INFORMATION 10 12 i5 MP Service Parts Accessories 11 13 Warranty 11 ...

Страница 3: ...re that has been optimally tuned to achieve maximum bass response and tonal balance For applications requiring extended low frequency enhancement a range of Tannoy sub bass systems are available and can be used in conjunction with the i5 MP 2 Unpacking Every Tannoy i5 MP is carefully tested and inspected before packing After unpacking please inspect your i5 MP for any damage sustained during trans...

Страница 4: ...ctor shielded cable microphone cable and wire the European pluggable type connector as shown in the chart below Pin 1 Ground Screen Pin 2 Positive ve Red Pin 3 Negative ve Blue 4 2 Powering Before connecting th e i5 MP to a mains inlet socket ensure all other connections are correctly made The i5 MP may be supplied with an IEC mains cable Connect this cable into the IEC mains socket on the back of...

Страница 5: ...ations As a result it will only need equalisation to compensate for difficult acoustic environments Excess equalisation can reduce system headroom and introduce phase distortion resulting in greater problems than it cures If equalisation is required then it should be applied gently and smoothly Violent equalisation will be detrimental to the overall sound quality If the loudspeakers were being use...

Страница 6: ...n demonstrated in Figures 8b 8c Figure 8a Figure 8b Figure 8c NOTE The installation of this product must be carried out in conformity with local building codes and standards If necessary consult your local safety standards officer before installing any product Alternatively check any laws or bylaws Tannoy will not be held responsible for any damages caused by the improper installation of any brack...

Страница 7: ...7 9 Performance Data Frequency Response Off Axis Frequency Response ...

Страница 8: ...8 Polar Plots 1 Octave Band Pink Noise ...

Страница 9: ...lack or White Connectors Balanced Phoenix style 3 terminal in unbalanced RCA in Fittings 2 x yoke fixing points 1 x female gimble plate Dimensions 223 5 H 162 6 W 153 0 D mm 8 81 H 6 41 W 6 03 D Weight 2 9kg 6lbs 5oz Accessories MB5Y and MB5B mounting brackets Shipping Dimensions 302 x 168 x 168mm 12 7 8 x 6 3 8 x 6 3 8 Shipping Weight 3 1kg 6lbs 15oz NOTES 1 Average over stated bandwidth Measure ...

Страница 10: ...t having a moulded plug at one end and a moulded mains plug appropriate to the country of use at the other end Where the moulded plug is fitted with a mains fuse always replace with the same type and rating If the fitted plug is unsuitable for your type of outlet sockets it should be cut off and disposed of safely in case it is inserted into a live socket elsewhere The wires in the mains cable are...

Страница 11: ...ontact your dealer or distributor in your country If you cannot locate your distributor please contact Customer Services Tannoy Ltd at the address given below Customer Services Professional Division Tannoy Ltd Coatbridge Scotland ML5 4TF Telephone 01236 420199 National 44 1236 420199 International Fax 01236 428230 National 44 1236 428230 International E Mail service tannoy co uk DO NOT SHIP ANY PR...

Страница 12: ...site www tannoy com Tannoy North America Inc 335 Gage Avenue Suite 1 Kitchener Ontario Canada N2M 5E1 Tel 519 745 1158 Fax 519 745 2364 e mail inquiries tannoyna com Website www tannoy com Tannoy Nederland b v Anthonetta Kuijlstraat 19 3066 GS Rotterdam Tel 010 286 0554 Fax 010 286 0431 e mail info tannoy nl Website www tannoy nl M L 2 nd October 2003 ...

Отзывы: