During Software upload various messages could be displayed:
Example:
In a 5.1 iDP
™
setup you are uploading monitor software to the entire system. As there are separate software files for
monitors and subs the following message should appear.
“5 Ellipse monitors updated successfully”
This means the Ellipse monitors are updated but no software has be accepted by the connected sub. If a monitor has lost
connection during transfer it will not be counted but the software upload continues.
If the message: “Failed to update Ellipse monitors” – is displayed, some of the monitors have reported an error during
software upload. This could be caused by communication errors. Please retry.
<OK>
Press to exit screen and execute AutoDetect command if marked.
System Setup
<Configuration>
Select your current setup.
<Analog Gain>
Range: +9dBu, +15dBu, +21dBu or +27dBu
Set to match analog Input gain to match the signal fed to
the optional Analog Input card.
<BNC Sync>
BNC Sync On:
The monitor attempts to lock on the World Clock BNC.