background image

CVS Series

CVS 6 (EN 54)

6" Coaxial In-Ceiling Loudspeaker for Installation Applications (EN 54 Certifi ed)

CVS 4 (EN 54) 

4" Coaxial In-Ceiling Loudspeaker for Installation Applications (EN 54 Certifi ed)

CVS 4 MICRO (EN 54)

4" Coaxial In-Ceiling Loudspeaker with Shallow Back Can for Installation Applications (EN 54 Certifi ed)

Содержание CVS Series

Страница 1: ... for Installation Applications EN 54 Certified CVS 4 EN 54 4 Coaxial In Ceiling Loudspeaker for Installation Applications EN 54 Certified CVS 4 MICRO EN 54 4 Coaxial In Ceiling Loudspeaker with Shallow Back Can for Installation Applications EN 54 Certified ...

Страница 2: ...Sde6 3mmodebayonetaprefijados Cualquierotra instalaciónomodificacióndebeserrealizadaúnicamente poruntécnicocualificado Estesímbolo siemprequeaparece leadviertedelapresenciadevoltaje peligrososinaislardentrodelacaja estevoltajepuedesersuficienteparaconstituirunriesgo dedescarga Estesímbolo siemprequeaparece leadviertesobreinstruccionesoperativas ydemantenimientoqueaparecenenla documentaciónadjunta ...

Страница 3: ...LICON BEHRINGER BUGERA et DDA sont des marques ou marques déposées de MUSIC Group IP Ltd MUSIC Group IP Ltd 2017Tous droits réservés Pourconnaîtrelestermesetconditionsdegarantie applicables ainsiquelesinformationssupplémentaires etdétailléessurlaGarantieLimitéedeMUSICGroup consultezlesiteInternetmusic group com warranty Vorsicht DiemitdemSymbolmarkierten AnschlüsseführensovielSpannung dassdieGefah...

Страница 4: ...rlevadoparaumcentroderecolhalicenciadoparaa reciclagemderesíduosdeequipamentoseléctricose electrónicos EEE Otratamentoincorrectodestetipo deresíduospodeterumeventualimpactonegativo noambienteenasaúdehumanadevidoasubstâncias potencialmenteperigosasqueestãogeralmente associadasaosEEE Aomesmotempo asuacolaboração paraaeliminaçãocorrectadesteprodutoirácontribuir paraautilizaçãoeficientedosrecursosnatu...

Страница 5: ...s ie BS 5839 1998 it is required that in the event of fire that failure of the circuit to which the loudspeaker is connected does not occur before evacuation of the building is complete Suitable measures include a use of terminal blocks for connection to primary with a melting point of not less than 650 C for example constructed from ceramic materials b use of terminal blocks of a lower melting po...

Страница 6: ...ws for Mounting Wings Rotary Switch Tuning Ports Cable Safety Tab Tuning Ports Mounting Wings Safety Tab Mounting Wings Cable Clamp 5 Accessories Standard Accessories Optional Accessories C Ring Tile bridge kit Note A tile bridge kit must always be used when installing into suspended ceiling tiles Paint Mask Cut out template Plaster Mud Ring ...

Страница 7: ...odes require use of this secondary support point which should connect to a separate secure support point using a suitable support line Consult construction codes in your region Go to section 7 for instructions on wiring and set up instructions 6 2 Installation Guide for SheetRock Ceilings 1 Mark the cut out area on the ceiling by tracing around the template provided Fig 1 2 Cut out the hole in the...

Страница 8: ...e the wiring cover at the back of the speaker can to access the Euro type connector plug and socket Feed the cable through the gland and attach the Euro type connector Fig 1 2 For connection to an amplifier use Pins 1 and 2 Fig 2 Pin 1 is positive Pin 2 is negative For connection to additional speakers in a distributed line pins 3 and 4 are in parallel where Pin 3 is negative Pin 4 is positive 3 T...

Страница 9: ...CVS 6 EN54 Dimensions CVS 6 EN54 Template Cut Out Size 250 mm 191 2 7 53 Ø213 0 8 39 Ø174 8 6 88 224 9 8 85 14 7 0 58 8 2 CVS 4 EN54 Dimensions CVS 4 EN54 Template Cut out Size 180 mm 236 0 9 30 262 0 10 35 15 9 0 63 Ø279 6 11 01 Ø244 6 9 63 ...

Страница 10: ... horizontal 125 vertical 157 horizontal 157 vertical 155 horizontal 155 vertical 4 kHz 70 horizontal 66 vertical 85 horizontal 85 vertical 86 horizontal 88 vertical Transducers Low Frequency 150 mm 6 mineral loaded cone material 100 mm 4 mineral loaded cone material 100 mm 4 mineral loaded cone material High frequency 19 mm 0 75 coaxially mounted 19 mm 0 75 coaxially mounted 19 mm 0 75 coaxially m...

Страница 11: ...o readtheterms andconditionsofourwarranty ifapplicable 2 Malfunction Shouldyour MUSIC Group AuthorisedResellernotbelocatedinyourvicinity youmaycontactthe MUSIC GroupAuthorisedFulfillerfor yourcountrylistedunder Support attannoypro com Shouldyourcountrynotbelisted pleasecheckifyour problemcanbedealtwithbyour OnlineSupport which mayalsobefoundunder Support attannoypro com Alternatively pleasesubmita...

Страница 12: ......

Отзывы: