Architectural Specifications

The Ceiling Monitor System shall consist of a 200mm (8.00") full range, point source, constant directivity Dual ConcentricTM transducer and passive frequency
dividing network mounted in a vented, injection moulded, paintable front baffle in UL94V-0 ABS material.

The back can in both PI (pre-install) & BM (blind-mount variants) shall be constructed of zinc plated steel. A recessed termination box shall be integrated with
the back can, a removable locking connector with screw terminals for secure wire termination with "loop through" facility shall be provided. Strain relief will be
provided by a clamping mechanism for use with plenum rated cable or conduit.

For pre-wiring the PI (pre-install) back can is provided with conduit knockouts (19mm/22mm/28mm, 0.75"/0.87"/1.14"). A safety ring is located on the rear of
the backcan for a load bearing safety bond.

Performance of the Ceiling Monitor System shall meet or exceed the following criteria: The system shall have a conical coverage pattern of 100 degrees
(1kHz to 6kHz). Frequency response measured on axis shall be 40 Hz - 35kHz (-10dB from rated sensitivity, measured in an IEC baffle in an anechoic chamber)
with no equalization. Sensitivity shall be 92dB (1W @ 1m). Long term power handling capacity as defined in EIA-426B test shall be 90W, recommended
amplifier power 180W. Dynamic high frequency protection is provided for occasional overpowering. The nominal system impedance shall be 8 Ohms (in low
impedance setting).

The Ceiling Monitor System shall be equipped with a 60W high performance line transformer for use in 70.7 or 100 Volt distributed audio systems with 60,
30, 15, 7.5* Watt taps available. An easily accessible rotary switch located on the front baffle shall be available for selecting transformer and low impedance
settings. A weather resistant perforated steel grille covers the transducer and switch.

Two support rails and one C-Ring shall be included with the ceiling monitor system.

Bezel diameter 325mm (12.80")
BM Front of ceiling to rear of back can 310.50mm (12.22"), Front of ceiling to top of safety loop 327.80mm (12.90")
PI Front of ceiling surface to rear of speaker unit 118.70mm (4.67"), Front of accessory back can bezel to top of safety loop 168.50mm (6.63")

The Ceiling Monitor System shall be the...CMS801 DC.

*70 Volt only

CMS801 DC

CMS801 DC data file // issue 1.07// 15.07.08

Tannoy adopts a policy of continuous improvement and product specification is subject to change.

[email protected]

Содержание CMS801 DC BM

Страница 1: ...inherent in two way discreet designs This high power and high sensitivity design with extended frequency response and very low distortion is equipped with dynamic high frequency protection This compact unit is specifically designed for applications requiring the combination of premium sonic quality for music and speech reinforcement and exceptional reliability and intelligibility Two CMS801 DC mod...

Страница 2: ...onstant directivity driver with multi fibre paper pulp cone 1 x 25mm 1 00 titanium dome with neodymium magnet system Physical Enclosure Back can Baffle Grille Safety Features Clamping Design Min Max Clamping Range Recommended Clamp Torque Back Can Options Blind Mount BM Pre Install PI Cable Entry Options Conduit Knockouts Connectors Safety Agency Ratings pending BM Hole Cutout Diameter PI Hole Cut...

Страница 3: ...0000 1m on axis frequency response 0 10 20 30 40 1 10 100 1000 10000 100000 Impedance vs frequency Frequency Hz 0 30 60 90 120 150 180 210 240 270 300 330 360 100 1000 10000 Beamwidth vs Frequency Frequency Hz 1 10 100 100 1000 10000 DI vs Frequency Frequency Hz Tannoy adopts a policy of continuous improvement and product specification is subject to change anfragen tannoy com 50 60 70 80 90 100 10...

Страница 4: ...2 5kHz 16 0kHz 20 0kHz CMS801 DC data file issue 1 07 15 07 08 48 36 24 12 0 0 30 60 90 270 300 330 48 36 24 12 0 0 30 60 90 270 300 330 48 36 24 12 0 0 30 60 90 270 300 330 48 36 24 12 0 0 30 60 90 270 300 330 48 36 24 12 0 0 30 60 90 270 300 330 48 36 24 12 0 0 30 60 90 270 300 330 Tannoy adopts a policy of continuous improvement and product specification is subject to change anfragen tannoy com...

Страница 5: ...E CUTOUT SIZE 295mm 11 61 CMS801 DC PI CMS801 DC data file issue 1 07 15 07 08 327 8 12 90 5 0 0 20 310 5 12 22 286 4 11 27 325 0 12 80 5 0 0 20 118 7 4 67 325 0 12 80 286 4 11 27 Tannoy adopts a policy of continuous improvement and product specification is subject to change anfragen tannoy com ...

Страница 6: ...RING CMS801 DC data file issue 1 07 15 07 08 10 00 0 39 293 00 11 54 70 00 2 76 180 00 7 09 205 00 8 07 230 00 9 06 255 00 10 04 280 00 11 02 305 00 12 01 650 00 25 59 366 00 14 41 397 0 15 63 291 4 11 47 365 0 14 37 8 8 0 35 151 2 5 95 168 5 6 63 293 00 11 54 366 00 14 41 80 00 3 15 192 00 7 56 192 00 7 56 Ordering Information Part number 8001 4550 8001 4560 8001 4650 8001 4570 7600 1658 Model na...

Страница 7: ...in an IEC baffle in an anechoic chamber with no equalization Sensitivity shall be 92dB 1W 1m Long term power handling capacity as defined in EIA 426B test shall be 90W recommended amplifier power 180W Dynamic high frequency protection is provided for occasional overpowering The nominal system impedance shall be 8 Ohms in low impedance setting The Ceiling Monitor System shall be equipped with a 60W...

Страница 8: ...CMS801 DC NOTES CMS801 DC data file issue 1 07 15 07 08 Tannoy adopts a policy of continuous improvement and product specification is subject to change anfragen tannoy com ...

Отзывы: