4 – Thermal Chambers

• Used to keep the “blocks” warm.
• Has programmable 

   temperature control.
• Removable transfer trays.

3 – LED Light Control

• Press      key, the LED light

   will become brighter.
• Press      key, the LED light

   will become darker.

A – Left Arrow
B – Right Arrow
C – Auto/Manual
D – Small Cryo

       Plate On/Off
E – Minus Key
F – Plus Key
G – Set Key

A

D

B

C

E

F

G

1 – Paraffin Tank

• Holds up to 6 liters of paraffin.
• Temperature can be adjusted

   in a range from 0° to 85°C.
• The reservoir has overheat 

   protection in the event of a 

   temperature control failure.

LCD Display Screen

2 – Main Control Panel

• To light up screen, press 

   any key 

(except CRYO)

.

• The screen will enter into 

   protection and power save mode 

   after 15 minutes of no contact.

5 – Paraffin Dispenser 

• Has programmable 

   temperature control.
• Flow control is adjustable.

Tanner Scientific® TN1500 - Embedding Center  7

Image 5.2

7 – Paraffin Waste Trays

• Two removable trays are located 

   under the heated work areas to 

   collect the excess paraffin 

   drained from the surface.
• Empty and clean both trays daily.

6 – Small Cryo Plate

• Located directly in front of 

   the embedding area to ensure 

   consistent, low temperatures 

   during the filling of the molds.
• Set temperature allows cryo plate 

   to cool to maximum ability.

8 – Hot Plate 

• Features a paraffin trimmer 

   on both the left and right side.
• Has programmable

   temperature control.

9 – Forceps Holder

• Maintains independent temperature.

Содержание TN1500

Страница 1: ...User Manual TN1500 Embedding Center Read Prior to Operation Always keep this manual near the unit User Manual WP46818 06 02 15 ...

Страница 2: ......

Страница 3: ...Warranty Service 15 9 Troubleshooting 16 Contents 6 1 Main Control Panel Setup Page 11 6 2 Temperature Setting 11 6 3 Timer Setting 12 6 4 Clock Setting 13 6 5 Running Manual Mode 13 6 6 Cooling Plate Operation 14 User Manual TN1500 Embedding Center 888 708 5233 Info TannerScientific com www TannerScientific com Tanner Scientific TN1500 Embedding Center 1 ...

Страница 4: ...sto trimmers on both ends of the hot plate are convenient for both left and right hand users Adjustable magnifier for easy viewing Two modes of operation automatic and manual Temperature control functions located on 5 parts Multiple over heat protection devices Keys with light indicator Low voltage and adjustable LED illumination system w adjustable flow tube Two module configurable options left t...

Страница 5: ...uct Do NOT operate the instrument around any electromagnetic interference Do NOT place the instrument near any explosive or flammable materials Do NOT place the instrument in an area where it would be exposed to direct sunlight The back of the instrument MUST be placed at least 15cm away from the wall If the instrument is placed closer than 15cm from the wall it can cause substantial damage to the...

Страница 6: ...ed Separately Separate Temperature Control Warm Up Time Prior to Operation Paraffin Reservoir 0 C to 85 C 2 hrs Paraffin Dispenser 0 C to 85 C 15 20 min Thermal Chambers 0 C to 85 C 15 20 min Hot Plate 0 C to 85 C 15 20 min Cold Plate 0 C to 10 C 30 min Forceps Holders 0 C to 85 C 15 20 min Working Environment Operate in an ambient temperature range of 5 40 C Humidity should be less than 80 Atmosp...

Страница 7: ...ting The paraffin reservoir mold warmer cassette bath work area and forceps holders are all hot Make sure the power supply complies with the specified requirements before use Only connect to a grounded socket The unit must not be exposed to direct sunlight or set up near an air condition vent The back of the instrument must be placed at least 15cm from the wall Attention Use heating elements only ...

Страница 8: ... Control Panel 3 LED Light Control 4 Thermal Chamber 5 Paraffin Dispenser 6 Small Cryo Plate 7 Paraffin Waste Trays 8 Hot Plate 9 Forceps Holder 10 Rear Panels On Back of Instrument 11 Cooling Plate 12 Cooling Plate Control Panel 1 4 2 3 5 9 11 12 6 7 8 6 Tanner Scientific TN1500 Embedding Center ...

Страница 9: ...ess any key except CRYO The screen will enter into protection and power save mode after 15 minutes of no contact 5 Paraffin Dispenser Has programmable temperature control Flow control is adjustable Tanner Scientific TN1500 Embedding Center 7 Image 5 2 7 Paraffin Waste Trays Two removable trays are located under the heated work areas to collect the excess paraffin drained from the surface Empty and...

Страница 10: ...et C Power Socket D Grounding Wire Connector E Back Cover Panel components may change depending on date of manufacture A D B C A Main Power Switch Socket B Foot Switch Socket C Grounding Wire Connector D Socket for Cooling Plate A D B C E 8 Tanner Scientific TN1500 Embedding Center Image 5 4 Image 5 3 ...

Страница 11: ...ndicator C Set Key D Increase E Decrease Cooling Plate Control Panel LCD Display Screen Image 5 6 Image 5 5 Cooling Plate Power switch is located on the rear of the instrument Reference Image 5 4 Has programmable temperature control Prior to operation the cooling plate should be dry and free of paraffin to prevent frost buildup ...

Страница 12: ...r plug into the instrument before plugging into the electrical socket Starting Up the Machine Turn on the main switch of the instrument Reference Image 5 3 on page 8 for power switch location LCD display screen on the main control panel will show the following picture Getting Started Please ensure that all preparatory steps have been completed and safety precautions have been reviewed prior to use...

Страница 13: ...tomatically recorded on the computer chip When restarting the embedding center and pressing the AUTO MAN key it will run according to the pre set parameters SETUP SCREEN 1 Select 1 TEMPERATURE using the keys 2 Press SET key to enter into temperature setting status 3 Choose the working zone 4 Use or to increase or decrease the temperature figures 5 Once you have selected your desired temperature ra...

Страница 14: ...ay NOTE If the instrument is turned on according to a pre set starting time it will automatically start to work at that time in automatic mode Suggested Pre Setting Temperatures for these 6 Working Zones 1 Paraffin Tank 65 C 3 Hot Plate 55 C 5 Paraffin Dispenser 67 C 2 Right Thermal Chamber 65 C 4 Left Thermal Chamber 55 C 6 Small Cryo Plate NOTE Paraffin dispenser should always be 2 3 C higher th...

Страница 15: ...instrument press AUTO MAN key on the main control panel to enter into the manual interface 2 Press to enter into running mode Heating icons will appear meaning all areas are warming up 3 Press to return back to waiting mode MAN MODE Off Work FRI 18 40 RIGHT 65 C LEFT 55 C CRYO PARAFFIN 65 C HOT PLATE 55 C DISPENSER 67 C AUTO MODE Running FRI 18 40 RIGHT 65 C LEFT 55 C CRYO PARAFFIN 65 C HOT PLATE ...

Страница 16: ...to be achieved There are two indicator lights beside the screen If the indicator light underneath is on this means the compressor is working If the indicator light on top is on this means the compressor has stopped working If the actual temperature is lower than setting temperature the compressor will automatically stop running When the actual temperature is higher than setting temperature the com...

Страница 17: ... Scientific at 888 708 5233 for more information Tanner Scientific will not be responsible for the damage and other problems caused by abuse and misuse of the instrument Service Information If you require any service or parts during the warranty period please contact Tanner Scientific at 888 708 5233 or the sales agent who sold you the unit Prior to calling please have the instrument model and ser...

Страница 18: ...Use hair dryer to melt wax around switch if necessary Contact technical support No flow of paraffin liquid or leak Faulty magnetic valve Contact technical support Sound is good as magnetic valve starts up but no flow Paraffin low Other things in magnetic valve Clean the paraffin screen Not enough time for melting continue heating Contact technical support Light is twinkling when turned on Unstable...

Страница 19: ...tific has no obligation to update the present manual periodically and on a continuing basis according to the latest technical developments nor to provide customers with extra copies or updates of this user manual This document is protected under copyright laws Any reproduction of illustrations or text requires prompt documented consent by Tanner Scientific Statements drawings illustrations and oth...

Страница 20: ...1073 Tallevast Rd Sarasota Florida 34243 888 708 5233 Info TannerScientific com www TannerScientific com ...

Отзывы: