background image

5. Assembly Instructions 

1. Carefully remove all components from the box.

2. Place all items on the floor side by side. Make sure not to excessively pull the wire harness that 

connects the base (1) to the top assembly (6).

3. Carefully 

pull wire harness

on topside of lower pillar (2) as pillar is inserted into the base (1). This will

minimize the length of straight wire and ease assembly.

4. Once the lower pillar (2) is placed firmly in the base (1), tighten the knob (3) to the threaded stud located

underneath the base.

5. Snap the top assembly (6) into the lower pillar assembly (2). Make sure to push in the excess length of

coiled wire harness (8) into the open ends of the two pillars as you bring them together. 

Be careful not

to pinch the coiled wire harness (8) between the two pillars.

6. Assemble the height rod arm (7) to upper height rod (5) from the bottom of upper height rod. 

7. Assemble the top height rod assembly (5) to the lower height rod (4). Slide the assembled height rod 

into the height rod opening on the pillar assembly. Push all the way down.

Note:

For scales without height rod skip steps 6 & 7.

5

List of Components

Base (fully assembled and 
pre-wired to display assembly)

Lower Pillar Assembly

Tightening Knob

Lower Height Rod Assembly

Top Height Rod Assembly 
(fully assembled with pivoting 
height measuring lever) 

Top Head Display Assembly 
(fully assembled and 
pre-wired to base)

Height Rod Arm

Wire Harness

1

2

3

4

5

6

7

8

1

2

7

3

4

5

6

8

If the scale is to be disassembled,
please use this plastic tool to 
separate the two pillars.

7

5

Содержание WB-300

Страница 1: ...ortant Notes for Users 2 Handling Tips Moving the Scale Disabling Key Sounds Changing Measurement Units 3 Components 3 4 Key Operation 4 5 Assembly Instructions 5 6 Before Use 6 Level the Scale Insert the Batteries Remove the LCD Cover Set up the Clock Setting to Zero 7 Instructions for Use 8 Weighing Procedure Auto on Function Turn on Function Wake up Function Measuring Height Procedure 8 General...

Страница 2: ... or extreme temperature change Never submerge in water or spill chemical liquids To clean use a dampened cloth and mild detergent If the product will not be used for a long period remove the batteries before storage Moving the Scale The scale has two rear wheels on the back of the platform To avoid damage use the wheels when moving the scale Hold the display head securely and tilt the scale back a...

Страница 3: ...24 1 4 LB 2 3 4 1 WB 300 7 6 8 Standard Features WB 300 WB 300MH WB 300DH Measuring Platform Weight LCD Clock LCD Battery Compartment Height Rod Arm For WB 300MH and WB 300DH Height Rod Sliding Block Upper Pillar Column Four feet on the bottom of platform 1 2 3 4 5 6 7 8 WB 300MH WB 300DH 5 ...

Страница 4: ...4 Key Operation 4 Weight LCD Right Side Clock LCD WB 300DH version only Right Side Clock LCD WB 300 and WB 300MH versions only ...

Страница 5: ...illars as you bring them together Be careful not to pinch the coiled wire harness 8 between the two pillars 6 Assemble the height rod arm 7 to upper height rod 5 from the bottom of upper height rod 7 Assemble the top height rod assembly 5 to the lower height rod 4 Slide the assembled height rod into the height rod opening on the pillar assembly Push all the way down Note For scales without height ...

Страница 6: ...ium battery in a separate bag The battery compartment is located on the back of the LCD display 1 Press down and pull battery compartment locking clip to remove the battery compartment cover 2 Insert batteries with the correct polarity 3 Replace the battery compartment cover and push it until you hear it click 6 AA alkaline AA alkaline AA alkaline LITHIUM BATTERY CB123A OR CR17335 SEE INSTRUCTION ...

Страница 7: ...clock LCD Note After 5 seconds or more of keypad inactivity during this process the adjusted clock will be saved automatically When you change or re install the lithium battery the clock setting will be reset to 12 00 pm Please follow the instructions above to reset the clock Changing the 3 AA batteries will not cause the time setting loss Setting to Zero Zero function enables the user to reset th...

Страница 8: ...l automatically shut off If the user remains on the platform the Weight LCD will display the weight for 20 seconds then automatically shut off Note If the weight is less than 30 lb the Auto On function will not work Please follow Turn on Function instructions listed below Turn on Function When the scale is in off mode and the user is not on the scale press any key to turn the power on 1 Press any ...

Страница 9: ...LCD Hold sign will appear in the upper left corner of the Weight LCD 3 Step off the scale The Weight LCD will display the weight for 10 seconds then the scale will automatically shut off If the user remains on the platform the Weight LCD will display the weight for 20 seconds then automatically shut off Note DO NOT press any key while the scale is waking up and before the weight has been locked in...

Страница 10: ...n the platform Place hand on the Height Rod Arm If the subject is taller than 44 pull the Height Rod Sliding Block and Height Rod Arm at the same time upward so that the arm is positioned higher than the subject s head If the subject is shorter than 44 move the Height Rod Arm down 10 INCORRECT way to hold the Height Rod Arm CORRECT way to hold the Height Rod Arm To avoid danger of breaking or comi...

Страница 11: ...lar Column see example 1 If the subject is shorter than 44 read the number below the Height Rod Arm see example 2 11 INCORRECT way to measure the height of 44 or more CORRECT way to measure the height of 44 or more 92 36 35 91 90 89 88 144 57 58 44 43 145 146 147 112 111 110 109 108 Reading the height measurement of 44 or LESS Reading the height measurement of 44 or MORE Example 1 58 147 5 cm Exam...

Страница 12: ...h clock for two seconds Please replace with three new AA alkaline batteries immediately Please refer to Inserting Batteries for instructions If you see Ad Er or nobAt on the weight LCD make sure the batteries are properly installed and have contact with the battery chamber The clock on this scale is operated by one replaceable 3 volt CR123 Lithium battery If the lithium battery is low LOWBATT icon...

Страница 13: ...ale After battery replacement the scale may need to be reset in the following situation 1 If the batteries were installed in the incorrect polarity after being replaced in the correct polarity 2 When the low battery sign s is still displayed even after the new batteries are installed In order to reset the scale take a ball point pen to push a button hidden behind the lithium battery Please reprogr...

Страница 14: ...Tanita France S A Villa Labrouste 68 Boulevard Bourdon 92200 Neuilly Sur Seine France Tel 33 0 1 55 24 99 99 Fax 33 0 1 55 24 98 68 www tanita fr Tanita Health Equipment H K Ltd Unit 301 303 3 F Wing On Plaza 62 Mody Road Tsimshatsui East Kowloon Hong Kong Tel 852 2838 7111 Fax 852 2838 8667 Tanita Europe GmbH Dresdener Strasse 25 D 71065 Sindelfingen Germany Tel 49 0 7031 6189 6 Fax 49 0 7031 618...

Отзывы: