This equipment is electronic device. Please 
dispose of this equipment appropriately as 
not  the  genera  l  household  waste  but 
electronic  equipment.  Please  follow  a 
regional regulation when you dispose of this.

This product meets the following requirements ;
1. Non-Automatic Weighing  Instruments (2009/23/EC)
2. Medical Device Directive (93/42/EEC)

3. RoHS Directive (2011/65/EU)

Copyright © 2013 TANITA Corporation. All Rights Reserved.

WB1507611(0)-1306FA

<EU representative>

www.tanita.com.cn

www.tanita.asia

  Room 8005, 877 Huai Hai Zhong Lu, Shanghai, 

  People's Republic of China

  Tel : +86-21-6474-6803

  Fax: +86-21-6474-7901

  Unit 301-303,Wing On Plaza, 3/F., 62 Mody Rord, 

  Tsimshatsui East, Kowloon, Hong Kong

  Tel : +852-2834-3917

  Fax: +852-2838-8667

http://www.tanita.com

  2625 South Clearbrook Drive, 

  Arlington Heights, Illinois 60005, U.S.A.

  Tel : +1-847-640-9241

  Fax: +1-847-640-9261

Hoogoorddreef 56-E, 1101 BE Amsterdam, The Netherlands   Tel: +31-20-560-2970   Fax: +31-20-560-2988   http://www.tanita.eu

1-14-2, Maeno-cho, Itabashi-ku, Tokyo, Japan   Tel: +81 (0) 3-3968-7048   Fax: +81 (0) 3-3967-3766   http://www.tanita.co.jp

www.tanita.co.in

  A-502, Mittal Commercia, Off. M. V. Road (Andheri Kurla Road), 

  Marol, Andheri-East, Mumbai 400 059 INDIA

  Tel : +91-22-3192-6107

  Fax: +91-22-2859-9143

(Shanghai) Trading Co., Ltd.

Power Source

AC adapter (FW7333SM/09 CLASS 

)

Input Voltage  :  100V

AC - 240V

AC

  

50 - 60Hz/200mA

 

Output Voltage  :  9V

DC

  Rated Current  :  800mA
         Plug Type  :  Centre Minus
Internally Powered Equipment (Battery Mode) 
LR6 (AA Alkaline battery) x 6, (Not included)

Specifications

approximately 100 hours of continuous use when using LR6

(AA Alkaline battery)

Battery Life

TYPE

WB-150MA

Strain Gauge Load Cell

±0.1kg

270kg

2kg

159

×

209

×

56mm

301

×

336

×

82mm

336

×

515

×

845mm

2m

5Digits LCD, Height of numerals 38mm

RS-232C (D-sub 9pins Female Connector)

+5˚C to +35˚C

30% to 80% (without condensation)

5.1 kg (except battery)

Weight Measurement

Measurement System

Max

Min

Accuracy at first calibration

0.1kg

e

-20kg

T

Display

Platform

Cable Length

Display

Output Data Interface

Temperature Range of usage

Relative Humidity

Weight of Equipment (Remote Display Version)

7.1 kg (except battery)

Weight of Equipment (Column Mounted Version)

Size

(Remote Display Version)

Size (Column Mounted Version)

Accuracy Grade

Safety Standard :  EN60601-1

IEC60601-1

EMC Standard   :  EN60601-1-2

IEC60601-1-2

Disposal

MDD

Class 

m

Class 

NAWI

Содержание WB-150MA

Страница 1: ...ative Humidity 30 80 no condensation Maximum Altitude 3 000m ASL Pressure 86kPa 106kPa Temperature 10 C 60 C Relative Humidity 10 90 no condensation Storage Conditions Usage Conditions To avoid malfunctions avoid storing the equipment in a location that is subject to direct sunlight significant temperature changes dampness large amounts of dust the risk of vibration or impact or near naked flames ...

Страница 2: ... can be used to certify weights and or business transactions It can be used to obtain reference data during medical examinations such as peri odic checkups and can help the prevention of obesity Measurements can be taken quickly and easily causing minimal inconvenience to the patient during measurements ...

Страница 3: ...stallation of the Equipment Remote Display Version Installation of the Equipment Column mounted version 12 Preparing the Power Supply Before use 3 Operating Instructions 13 Preparation Automatic power off to save battery life 13 Preparation Weight Lock Mode 14 Preparation Confirmation Software Version Number 14 Measuring Weight 15 How to use 4 Output Data Format 18 5 Troubleshooting 19 Specificati...

Страница 4: ...wired outlet Only genuine cables and equipment can be used Do not use a multi plug adapter Doing so may cause fire Failure to follow instructions highlighted with this mark could result in death or severe injury Failure to follow instructions highlighted with this mark could result in injury or damage to property Keep this equipment away from flammable gas and oxygen rich environments This section...

Страница 5: ...d unplug the AC Adapter from the wall socket If the equipment will be out of use for a prolonged period remove the batteries before storing the equipment The data provided by this equipment should be interpreted by a licensed professional Be sure to clean the scale platform with the appropriate disinfectant after each use Prohibited Always If an anomaly in the user or equipment is discovered take ...

Страница 6: ...lectrodes etc for wear or damage Documentation for the current equipment model 3 Visually inspect the following at least monthly Screws on equipment Do not wipe the equipment with corrosive chemicals benzene cleaner etc Please use a neutral detergent to clean the equipment The warranty will be invalidated if an unauthorised person attempts to disassemble or repair any of the parts of this equipmen...

Страница 7: ...sing dry cell batteries When using the AC Adapter Loosen the screw to slide the Battery Compartment out In case of emergencies keep the area around the outlet clear while operating this equipment GB Before use How to Measure Correctly ...

Страница 8: ...splay Box Battery Compartment Platform Adjustable Feet AC Adapter MODEL FW7333SM 09 Instruction Manual Fixing Screw for the Bracket x 2 Accessories Accessories Battery Compartment Platform Adjustable Feet AC Adapter MODEL FW7333SM 09 Instruction Manual Screws x 3 Column Mounted Version Level Gauge Display Box GB Before use Product Assembly and Components ...

Страница 9: ...f manufacture Follow operating instructions 9 Control Panel STEP ON Start measuring weight Net Net PT Indicates that the tare value is input Weight Lock Mode Indicates that the Weight Lock function is activated Weight Lock Indicates that the Weight is locked Stabilized Indicates that the displayed figure has stabilized Turn power ON Scale reset to zero Tare Decrease numerical value Turn Weight Loc...

Страница 10: ...measurement place the equipment on as flat a surface as possible and adjust the level with the adjustable feet so the bubble in the level gauge is in the centre of the frame Pull out the stand at the back of the display box When putting away the display box insert the stand in the slot on the back of the display box There is a danger that the Display Box may fall down if it is not fixed securely A...

Страница 11: ...e column before use Connect the connectors on the platform and column Turn the platform over Screw the column to the platform using three screws Insert the connector into the column 2 1 3 4 2 1 3 4 Ensure that the cable does not become wrapped around the screws Note GB Before use Product Assembly and Components ...

Страница 12: ...If the polarity is incorrect the batteries may leak and damage the equipment Remove the batteries before storing the equipment if it is not to be used for a long time Insert the AC adapter jack into the DC jack socket of the Display Box and insert the AC Adapter plug into a wall socket Check that the Pilot Lamp on the AC Adapter lights Unscrew the Fixing Screws for the Battery Compartment on the r...

Страница 13: ...ave battery life Press when there is nothing on the scale is displayed Press while is displayed and select the automatic power off time by pressing or After selecting the automatic power off time press to set the input time When is displayed the setting is completed 5minutes 10minutes 30minutes 60minutes Inactivate How to use Operating Instructions GB Turn on the power by pressing After flashes is...

Страница 14: ...hen the weight lock mode is enabled Weight Lock Mode mark is indicated in the display When the weight lock function is enabled the measurement value is locked after the load is stabilized When the weight is locked the Weight Lock mark is indicated in the display 1 2 3 Preparation Confirmation Software Version Number Press when there is nothing on the scale is displayed Select by pressing or Press ...

Страница 15: ...ntre of the platform After load is stabilized Stabilized mark is indicated Step off the scale When use Preset Tare functions Press in no load Net PT mark PT mark and flushes Input preset tare value by or within 20 0kg 0 1kg increments Set input preset tare value by Turn on the power by pressing After flashes is displayed 1 Turn on the power by pressing After flashes is displayed 1 2 3 4 5 2 3 or ...

Страница 16: ...cancelled temporarily is displayed When inactivate preset tare function please set preset tare value to 0 0kg Press in using preset tare Input preset tare value by or within 20 0kg 0 1kg increments Net PT mark and PT mark are displayed Set input preset tare value by To change preset tare value Measuring Weight continued 1 2 1 2 or ...

Страница 17: ...s the key An arrow NET will appear next to the mark and 0 0kg will be displayed When weighing a person object including tare items the weight of the person object minus that of the tare items which is the net weight will be displayed To change the tare weight cancel the tare weighing function and repeat from step 3 When using the tare weighing function the measurement range is reduced by the tare ...

Страница 18: ...ion Explanation for RS 232C compliant output 18 GB Specifications Communication standard EIA RS 232C Communication method Asynchronous Signal speed 9 600bps Data bit length 8bit Parity NONE Stop bit 1bit Terminator CR LF Flow control None Signal line name and connection method Terminal no Signal name 1 2 TXD 3 Connection example WB 150MA PC etc 4 5 GND 6 7 8 9 This explanation is for the interface...

Страница 19: ...teries The batteries may have run out Confirmthat the equipment is working by using the AC Adapter or new batteries 5 Troubleshooting 19 Transmission data GB Transmission data is output immediately after measurement regard less of the status of the reception side e g PC Therefore the reception side must always be ready to receive data before any measurements are taken Commas are used to separate d...

Страница 20: ...ita co jp www tanita co in A 502 Mittal Commercia Off M V Road Andheri Kurla Road Marol Andheri East Mumbai 400 059 INDIA Tel 91 22 3192 6107 Fax 91 22 2859 9143 Shanghai Trading Co Ltd Power Source AC adapter FW7333SM 09 CLASS Ⅱ Input Voltage 100V AC 240V AC 50 60Hz 200mA Output Voltage 9V DC Rated Current 800mA Plug Type Centre Minus Internally Powered Equipment Battery Mode LR6 AA Alkaline batt...

Отзывы: