background image

 

 

 
 
Category 
 

 
Symptoms  of  major   
errors     and 
Trouble  shooting     

   

 

KD200 

Service  Manual

 

 
 
page 

 
 
   Page   7/10 

 

      

1

When  the  ON/TARE  button  is  pressed ,the  scale  does  not  turn  on . 

Confirming   Item 

Confirming content 

Repairing   method 

     The battery direction    Checking  the  battery  

direction      

Insert battries  in  position paying 
Colose  attention to 

+

-)

direction 

The  battery  voltage        4 batteries have a voltage  

higher  than  4V        

If  the voltage  lower  than  4V  please 
Exchange  4 batteries  simultaneously    

Wires  and  battery 
Contact  plate  solder       

According  to  item  1,2,3  on 
page 9  and  to  item  1,2,3,4,5 
6,7  on  page  10. 

Arrange  the  connection  in  correct 
order 

Plastic housing 

Checking  the switch  plastic      
is  deformed 

Exchange  the  cover  assembly  If  it  
is    deformed     

PCB   

Exchange  the  circuit-board  
assembly                 

No  problem 

Can  adjust   the 

contrast. 

                                                                                      
       (2)

   

0

or  weight  values  are  unstable                                                                                     

                                   

Confirming   Item 

Confirming content 

Repairing   method 

Temperature   range        Ensure  proper  temperature   

range 

Maintain a  constant  temperature  for 
1~ 2   hours     before  use                       

Effecting  as  vibration     Checking  excessive  vibration     Stop  vibration  or  move  to  a place 

with  little  or  no   vibration 

Effecting  as  wind            Checking  excessive  wind           Stop  wind  or  move  to  a   place  

with  little  or  no   wind 

Solder    

According  to  item  4,5  on 
page 9  and  to  item  8,9  on  
page 10             

Arrange  the  connection  in  correct 
order 

Screw   

Checking  the conation  screw   
M4

×

16      

Double shear  strength  must  be more 
than  0.6N

·

m                                         

Mixing   sundries 

According  to  item  28,29 on 
page  3 

Removing   sundries 

PCB    

Exchange   new PCB   

Adjust again 
 

 

       (3) 

   

0

doesn’t  exchange  after  the  weight  is  measured                                                       

                                                                                           

Confirming   Item 

Confirming content 

Repairing   method 

Solder 

According  to  item  4,5  on 
page 9  and  to  item  8,9  on  
page 10                           

Arrange  the  connection  in  correct 
order 

PCB 

Exchange   new PCB   

Adjust again 

                                                                                                                                                                     

Содержание KD-200

Страница 1: ...of product 2 2 Diagram of mechanism Assy 3 3 Parts List 4 4 Calibration 5 5 Specification chart 6 6 Trouble shooting 7 7 Diagram of wiring DC 9 8 Diagram of wiring DC 10 Symbol Description Page Date Name Approved by Approved by Checked by Designed by Establishment Apr 17 2002 TANITA CORPORATION Dongguan ...

Страница 2: ......

Страница 3: ......

Страница 4: ...e B 1 10 Battery contact plate C 1 11 PCB Assy 1kg 2kg 5kg 1 12 Name plate 1 13 Name plate of side 1 14 Rubber foot 4 15 Screw M4 16 4 16 Screw M4 20 4 17 Screw M4 40 4 18 Screw M3 5 2 19 Screw M3 12 4 20 Screw M5 20 4 21 Screw M4 20 2 22 Nut M4 2 23 Filter PCB AC use only 1 24 DC jack AC use only 1 25 DC jack seal AC use only 1 26 Mechanism 1kg 2kg 5kg 1 27 Mechanism holder 2 28 Flexible sensor 1...

Страница 5: ...2capacity on the mechanism s platform 8 The screen will show о 2 in the stable situation 9 Place a 500g weight 1 2capacity on the mechanism s platform again 10 The screen will show 8888 for 1 5 seconds 11 Immediately the screen will show 0g Calibration finished 12 Remove the weight the screen will show 1000g 13 Push the ON button the screen will show 0g You can take measurement Notice 1 Notice the...

Страница 6: ...fication display 5000g 0g 2500g 5000g 5g 10g 4 2000g 0g 1000g 2000g 2g 5g 8 1000g 0g 500g 1000g 1g 2g о 5000g 11lb 0g 5000g 5g 0oz 11lb 0 2oz 0 2000g 70oz 0g 2000g 2g 0oz 70oz 0 1oz 0 1000g 35oz 0g 1000g 1g 0oz 35oz 0 05oz 2 5000g 0g 5000g 5g 2 2000g 0g 2000g 2g 4 1000g 0g 1000g 1g 6 4 8 о 2 4 6 О О 2 ...

Страница 7: ... Can adjust the contrast 2 0 or weight values are unstable Confirming Item Confirming content Repairing method Temperature range Ensure proper temperature range Maintain a constant temperature for 1 2 hours before use Effecting as vibration Checking excessive vibration Stop vibration or move to a place with little or no vibration Effecting as wind Checking excessive wind Stop wind or move to a pla...

Страница 8: ...xchange PCB the display is still error please return the scale to our manufactory for repairing 6 The specification on the name plate is not in accordance with reality The design specification is error please return the scale to our manufactory for repairing Notice When you exchange PCB use the only TANITA components Don t use other company components directly because it must be aujusted according...

Страница 9: ......

Страница 10: ......

Отзывы: