Category
Calibration
KD200
Service Manual
page
Page 5/10
Display
(1)
Make sure that the Scale is turned OFF.
(2)
Press and hold the OFF button ,and then click the ON button
3 times.
(3)
Release the ON button and OFF button simultaneously.
(4)
The screen will show
[
8888
]
for 0.5 seconds.
(5)
Then the screen will show
[
A
-о]
, A is the specification
Code. Please refer to P6 for details .Now for example of 1kg/
0~500g 1g 500~1000g 2g.
(6)
The screen will show
[о-
1
-]
in the stable situation
(7)
Place a 500g weight(1/2capacity) on the mechanism’s platform
(8)
The screen will show
[о-
2
-]
in the stable situation
(9)
Place a 500g weight(1/2capacity) on the mechanism’s platform again
(10)
The screen will show
[
8888
]
for 1.5 seconds
(11)
Immediately ,the screen will show
[
0g
]
, Calibration finished.
(12)
Remove the weight , the screen will show
[-
1000g
]
.
(13)
Push the ON button , the screen will show
[
0g
]
,You can
take measurement.
<Notice>
(1)
Notice the environment .You’ll get incorrect figures as a result of vibration,
Wind ,or the improper temperature.
(2)
Notice the accuracy of the weight for
Calibration.
(3)
If the scale display is in conflict with the specification chart ,please return
to the manufacturer.
8888
о-
0
-
о-
1
—
о-
2
-
8888
0
g
-
1000
g
0
g