background image

en

Measure your body composition and verify it against your registered details.

Auto-recognition data is displayed. Please make sure that the displayed data 

matches your registered content.

If heart rate measurement is turned on, the LCD changes to the heart rate 

measurement screen. Heart rate measurement starts after a countdown. 

A screen display indicates that heart rate measurement is in progress. Step down 

from the monitor when you hear a series of short beeps. 

The device automatically turns off after measurement results have been displayed.

 (Reviewing Measurement Results, pg. 18)

Return the control panel to its original position after reviewing your measurement 

results.

Weight is displayed.

14

If the auto-recognition function discovers multiple possible candidates for the current user, the device automatically switches 

to the ID selection mode after body composition measurement is complete (pg. 15).

    Select your ID number using the       and       buttons, then press       to confirm.

    *If the device repeatedly switches to ID selection mode, enter your ID before conducting a measurement (pg. 15).

If you forget to turn off the power, the device automatically turns off (display turns off) in the following cases:

      

If no operations are performed on measuring platform for more than 60 seconds

      

If no weight is detected on the measuring platform at any time during measurement

      

If a single measurement result is displayed for more than 40 seconds

Note:

Содержание InnerScan Pro RD-545PRO

Страница 1: ...RD 545PRO Multi Frequency Body Composition Monitor with integrated Bluetooth technology Instruction Manual Please read this Instruction Manual carefully and keep it for future reference en ...

Страница 2: ...rements with Auto Recognition 13 Measuring with an ID Number Call Measurement 15 Taking Measurements Without Registering Guest User Measurements Weight Only Measurements 16 ID Selection Mode 17 Measurement In Progress 17 Reviewing Measurement Results Whole Body 18 Reviewing Measurement Results By Body Part 19 Reviewing Measurement Results Abnormal 20 Changing Personal Data 21 Erasing Personal Data...

Страница 3: ... passes a low level electrical signal through the body which may interfere with the operation of the implant Pregnant women should only use the weight function Other functions are not intended for use when pregnant Important Notes for Users This Body Composition Monitor is intended for adults and children age 7 17 who have inactive to moderately active lifestyles and adults with athletic lifestyle...

Страница 4: ...ht loss measures and exercise programmes based on self analysis could be harmful to your health Always follow the advice of a qualified professional Failure to follow instructions highlighted with this mark could result in injury or damage to property Do not use old batteries together with new batteries or a mix of different types of batteries at the same time Doing so may cause battery fluid to l...

Страница 5: ...ot use the monitor near other products such as microwave ovens that emit electromagnetic waves Doing so may cause the monitor to malfunction preventing accurate measurements Avoid excessive impact or vibration to the monitor Doing so may damage the monitor or cause it to malfunction or may cause setting to be erased Always 5 Avoid measuring after over eating or over drinking or when severely dehyd...

Страница 6: ... do not touch your body To ensure accuracy readings should be taken without clothing and under consistent conditions of hydration Always remove your socks or stockings and be sure the soles of your feet are clean before stepping on the measuring platform Be sure that the arch of each foot is aligned with the center of the measuring platform Don t worry if your feet appear too large for the unit ac...

Страница 7: ...ct the year using the and buttons 3 Press to confirm Set the day and hour in the same way The power automatically turns off after displaying the set region year month day and time Up Recall Button Weight Only Off Button SET Communication Button Down Item Select Button Display Screen Inserting the Batteries Note Be sure that the batteries are inserted in the correct orientation If the batteries are...

Страница 8: ...anita com after measurement Touch Save to return to the previous screen 4 Scale Settings Touch and follow the instructions in the App to register your platform Return to the previous screen 8 Initial Setup Type 1 Setup via Smartphone If you are not using an app enter settings manually in the body composition monitor pg 10 before using If you purchase a new smartphone be sure to adjust the registra...

Страница 9: ...gnal strength it may take a few seconds to connect to the body composition monitor 5 Operate the body composition monitor as indicated by the app 6 When the body composition monitor is activated is displayed 7 After is displayed hold the control panel and carefully step barefoot onto the measuring platform 9 Initial Setup Type 1 Setup via Smartphone Please refrain from moving during measurement Me...

Страница 10: ... is recalled when you turn the power on and step on the body composition monitor enabling you to use the device easily every day without the hassle of entering information each time Body composition must be registered Only take measurements while barefoot Place the body composition monitor on a hard flat stable surface Set button On Off button Up Down button 10 Initial Setup Type 2 From Body Compo...

Страница 11: ...remove the control panel from the device and carefully step barefoot onto the measuring platform The device automatically turns off after registered personal data and measurement results have been displayed Body Composition Registration 11 Initial Setup Type 2 From Body Composition Monitor Please refrain from moving during measurement Note You must connect your smartphone to the body composition m...

Страница 12: ...gh yourself while holding a smartphone first enter the amount of weight you want to subtract into Weight of Clothing etc The input amount will be subtracted from your weight display Up to 4 4 lb can be entered for Weight of Smartphone etc The amount entered in Weight of Smartphone etc is subtracted from your measured weight 0 440 lb Note Up to 10 measurements can be stored in the device per ID num...

Страница 13: ... the need to specify the user before use What is the Auto Recognition Function Taking Measurements with Auto Recognition In order to measure with the auto recognition function first enter your personal data pg 8 Measurements cannot be taken with auto recognition unless this information is registered If you have input a nickname into the app settings it is displayed in place of the ID number The au...

Страница 14: ...its original position after reviewing your measurement results Weight is displayed 14 If the auto recognition function discovers multiple possible candidates for the current user the device automatically switches to the ID selection mode after body composition measurement is complete pg 15 Select your ID number using the and buttons then press to confirm If the device repeatedly switches to ID sel...

Страница 15: ...e entered a nickname into the app settings and connected the body composition monitor to your smartphone your nickname is displayed instead of your ID number Enter your ID number and take measurements without using auto recognition Use this method if using auto recognition repeatedly causes the device to switch to ID select mode etc Place the body composition monitor on a hard flat stable floor 15...

Страница 16: ...ntrol panel to its original position Weight Only Measurements Guest User Measurements 16 Age can be set from 7 to 99 Note Please refrain from moving during measurement Measurements cannot be taken accurately if the control panel is being held or resting on the floor before is is displayed Note Taking Measurements Without Registering Guest User Measurements Weight Only Measurements If the auto reco...

Страница 17: ...seconds or more to switch to the ID selection mode and re select your ID The monitor and the control panel light up depending on the area being measured This is a useful indication of the progress of the current measurement 17 If you turn off the power without re selecting your ID number those measurement results are saved to the incorrect ID number Note ID Selection Mode Measurement In Progress E...

Страница 18: ...isplayed and then the power turns off after about 40 seconds The displayed item can be switched by pressing or while measurement results are being displayed The icons on the measurement result screen indicate either a positive or negative change since the last measurement was taken Press to view measurements of each body part Press to view measurements of each body part Press to view measurements ...

Страница 19: ...layed for trunk Persons aged 7 17 Weight BMI body fat percentage and heart rate are displayed Reviewing Measurement Results By Body Part Error is displayed if the body fat percentage is outside the measurement range Note To Cancel Press to cancel a selection or turn off the power The icon is lit on the measurement results display screen once your smartphone has been connected and measurement data ...

Страница 20: ...ities such as exercise or bathing a asterisk will appear next to the measurement in the measurement result screen To ensure accurate measurement of body composition we recommend measuring at a time when your heart rate is at a normal rate and avoid measuring immediately after exercising or bathing pg 12 A is also displayed next to heart rate measurement results for persons aged 7 17 as these are r...

Страница 21: ...well as any data stored in the device 1 Select using the and buttons 2 Press to confirm 3 After is displayed carefully step barefoot onto the measuring platform Measurement procedures pg 7 Adjusting Date of Birth Gender is displayed 21 Changing Personal Data You must connect your smartphone to use an app Set up the body composition monitor according to the Setup via Smartphone pg 8 instructions Pr...

Страница 22: ...Deleting personal data connected to a smart phone also causes measurement data to be deleted from the device 22 Erasing Personal Data Note Press to cancel a selection or turn off the power If you forget to turn off the power the device automatically turns off display turns off in the following cases If no operations are performed on the measuring platform for more than 60 seconds If no weight is d...

Страница 23: ...ition using Dual Frequency Bioelectrical Impedance Analysis BIA Safe low level electrical signals are passed through the body via the TANITA foot pads on the monitor platform The signal can flow easily through fluids in muscles and other body tissue but meets resistance as it passes through body fat because body fat only contains a small amount of fluid This resistance is called impedance The impe...

Страница 24: ...at percentage range for your age gender Overfat Above the healthy range Increased risk of health problems Obese Far above the healthy body fat range Greatly increased risk of obesity related health problems What Is Body Fat Percentage Body Fat Reference Curves for children Targeted at BMJ British Medical Journal Draft 1 AMP 19 June 2004 by Dr Andrew Gallagher D et al Am J Clin Nutr 2000 72 694 701...

Страница 25: ...rcentage ranges for a healthy adult are Female 45 to 60 Male 50 to 65 Source TANITA Research Note The total body water percentage will tend to decrease as the percentage of body fat increases A person with a high percentage of body fat may fall below the average body water percentage As you lose body fat the total body water percentage should gradually move towards the typical range given above Ap...

Страница 26: ...h more accurate and personalized reading for the user based on impedance measurements This method has been medically validated using indirect calorimetry measuring breathcomposition Reliability of the equation for Basal Metabolic Rate At 2002 Nutrition Week Scientific and Clinical Forum and Exposition Title International Comparison Resting Energy Expenditure Prediction Models The American Journal ...

Страница 27: ...er they have a high body fat percentage with low muscle mass level 3 Solidly built Large Frame Obese This person has both a high body fat percentage and a high muscle mass 4 Under exercised Low Muscle and Average Body Fat Percentage This person has an average body fat percentage and a less than average muscle mass level 5 Standard Ave Muscle Ave Body Fat Percentage This person has average levels o...

Страница 28: ...s important to maintain a good balance between muscle mass and quality More indicates a better state of muscle Max Note en 28 Muscle Quality Judgement Chart Balance Between Muscle Mass and Muscle Quality Muscle Quality Score may not be accurately evaluated if there are abnormalities in the state of body water such as in the following conditions If the body fatigued or swollen If the person is dehy...

Страница 29: ...scribed below may obtain varying readings and should take the values given for reference purposes only Elderly persons Women during or after menopause People receiving hormone therapy Estimated bone mass is a value estimated statistically based on its correlation with the fat free amount tissues other than the fat Estimated bone mass does not give a direct judgment on the hardness or strength of t...

Страница 30: ...ection between the app and device is only enabled when the device power is off Check that the device power is off then try again 8 Delete the device registration from the Settings Bluetooth settings on the smartphone then try pairing the device with the smartphone again 8 Has the individual data for the connected smartphone been deleted from the body composition device Delete the device registrati...

Страница 31: ...iving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or television technician for help Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by T...

Отзывы: