background image

GB

GB

5

4

Safety Notes

Caution Symbols

Thank you for purchasing this precision crafted Tanita product. For optimum per-

formance and safety, please familiarize yourself with the Caution Symbols below.

These symbols are designed to alert the user to potential hazards when using this

equipment. Ignoring these Caution Symbols may result in serious injury, or damage

to the product.

Please be sure to review before proceeding with the INSTRUCTION MANUAL.

• Inserting and Removing the AC adapter

To  reduce  the  risk  of  electric  shock  or  product  damage,  never  insert  or
remove the AC adapter with wet hands.

• Do  not  under  any  circumstances  dismantle  or  alter  the  device,  as  this

could result in electric shock or injury as well as adversely affect the preci-
sion of measurements.

• To prevent fire hazard

Use  only  a  correctly  wired  (230V  AC)  outlet,  and  do  not  use  a  multiple
outlet extension cable.

• Ensure the baby is lying down in the basket with minimal movement, as

any resultant fall or slip may cause serious injury.

• The  baby  basket  is  not  designed  to  accommodate  individuals  weighing

more than 15kg.

• As a safety precaution, infants must not be left unattended on the baby basket.

This symbol indicates the possibility of serious

injury  if  the  product  is  mishandled  or  instruc-

tions are ignored.
This  symbol  indicates  the  possibility  of  physi-

cal injury or equipment damage if instructions

are ignored.
This symbol indicates general precautions that

should be taken when using this product.

Warning

Caution

Warning

•To prevent the spread of infections,

Always clean the weighing platform after use.

Sterilize the platform with an appropriate alcohol-based cleaning fluid before each use.

•Installation of the equipment

Ensure the weighing platform is placed on a level and stable surface. If the equipment is

used when unstable, for example if not all feet are on a level surface,then there is a risk

that scale will tip over and it will be impossible to obtain an accurate measurement.

•Measurement

Always take the utmost care when placing a baby in the Baby Basket. Ensure that there

is no risk of the equipment tipping over.

To move the scale, hold it firmily by the main body.

•AC adapter

Only use the adapter supplied with this equipment (MODEL: A30930G).  Other

adapters may cause malfunctions.  The circuit board incorporates a fuse (100mA, 125V)

for electronic equipment.  If devices other than the original AC adapter are used, or a

large electrical current is applied, the fuse will be blown for safety purposes.  As the fuse

forms a fixed part of the unit and cannot be easily disassembled, please consult your

nearest Tanita sales office or agent if the fuse needs to be replaced.

•Battery

When changing batteries, ensure that the new batteries are inserted with the correct

poand -.

If the polarity is incorrect, then the batteries may leak and damage the equipment.

•How to handle the equipment when moving it

When carrying the equipment, please do not lift it up by the Baby Basket

Please move the equipment by holding the main body firmly.

•To avoid any risk of injury or malfunction, keep your fingers, and other objects away

from the space between the inner-plate and the scale.

Caution

This is a precision manufactured and accurately calibrated product. Please
observe the following instructions.

• Never disassemble or adjust the equipment, as this may cause malfunctions. The equip-

ment should only be inspected in accordance with the regulations in each country.

• When not in use for a long time, unplug the AC Adapter from the wall socket.

• When not in use for a long time, remove the batteries before storing the equipment.

• Do not wipe the equipment with corrosive chemicals (benzine, cleaner, etc.). Please use

a neutral detergent to clean the equipment.

• Avoid subjecting the equipment to excessive shocks or vibrations.

• If an unauthorised person attempts to disassemble or repair any part of the unit, the

warranty will become invalid. If the unit malfunctions, please consult your nearest

Tanita sales office or agent.

• Do not wash any part of the scale other than the basket with water.

• When disposing of this unit ,please do so in accordance with the disposal standard of

industrial waste in each country.

Maintenance

Applications

1.This equipment has been calibrated as a precision instrument and can be used to

certify babies’ weights and/or to certify business transactions.

2.It can also be used to obtain reference data during medical examinations, such as

periodic checkups, and to supervise babies’growth.

BD815MA̲GB

07.11.20, 11:34 AM

4-5

Содержание BD-815MA

Страница 1: ...g the TANITA digital baby scale For optimum performance and safety please read this manual carefully and keep it handy for future reference Professional Baby Scale BD 815MA INSTRUCTION MANUAL GB BD815MA GB 07 11 20 11 33 AM 1 ...

Страница 2: ...d Functions of Display Panel and Operation Keys 12 How to Use Power supply 14 How to Set Up Correctly 15 How to Use the Scale 16 When tare is not specified 16 Tare weighing function 17 Cancelling the tare function 19 Memory Function for Measured Values 20 Memory Function 20 Memory Value Recall Method 21 Display Weight Gain 21 Various Setting Methods 22 Display Hold Time 22 Auto Power Off Time 23 O...

Страница 3: ...ody AC adapter Only use the adapter supplied with this equipment MODEL A30930G Other adapters may cause malfunctions The circuit board incorporates a fuse 100mA 125V for electronic equipment If devices other than the original AC adapter are used or a large electrical current is applied the fuse will be blown for safety purposes As the fuse forms a fixed part of the unit and cannot be easily disass...

Страница 4: ...r shocks Instructions for Measurement Explanation of terminology Max Maximum Capacity This shows the maximum weight that can be measured by the scale Example In the case of Maximum capacity 15kg it can measure up to 15kg One exceeding the weighing capacity cannot be measured e Minimum Graduation This shows the amount of one scale mark In the case of a digital display this shows the inter val of th...

Страница 5: ...r Line 1 Slide the basket over the plat form until it stops Make sure the basket is firmly secured and then fix it to the platform by pushing in the lever Caution Make sure the basket can t drop Pull out the lever 1 While gently pushing down the lever slide out the basket in the displayed direction When the far ege is aligned with the stickered line the basket may be removed Caution The baby baske...

Страница 6: ... of accessories Instruction manual this book AC adapter Model A30930G R6 batteries 4 Measure sticker Battery cover Battery housing Operation keys Refer to page 13 AC adapter inlet Level gauge Lever Adjusters 4 RS 232C connector 10 11 Front Back BD815MA GB 07 11 20 11 35 AM 10 11 ...

Страница 7: ...is 5 g 1 MEMORY Sets the current weight in memory In set mode sets the display hold time 2 WEIGHT GAIN Indicate the weight difference between mem ory weight and current weight Set auto power off time 3 RECALL Recalls previous reading 4 WEIGHT LOCK ON OFF Sets the weight lock mode on or off 5 ON TARE Turns the power on or sets the tare 6 ZERO Scale resets to zero 7 OFF Turns power off 8 EXTEND Pres...

Страница 8: ...that the air bub ble in the level guide is positioned exactly in the centre Confirm that all four adjusters are in contact with the surface Level gauge Adjusters 4 Using the AC adapter 1 Insert the AC adapter jack into the AC adapter inlet on the right side of the main unit 2 Plug the AC adapter into the power outlet This equipment must be used with the included AC adapter Model A30930G Caution 2 ...

Страница 9: ...e stabilizes and the weight is con firmed STABILIZED and WEIGHT LOCK t is shown Beep sound 2Press the key to set the Weight Lock Mode Weight Lock Mode t is shown Measurement instructions A warning sound beeps if a baby is placed on the basket before g is displayed If it happens remove the baby from the basket Release Note When the load exceeds 6000 g the pointer besides the 5 g mark appears Cautio...

Страница 10: ...5 g when measuring weights over 6000 g B 1Remove the tare from the basket The tare function is automatically cancelled when the displayed load becomes g The scale switches to Minimum Graduation 2 g Note When the weight of loads over 6000 g is measured the scale will operate with Minimum Graduation 5 g as long as the load does not become 0 Therefore please note that if the weight of a second baby i...

Страница 11: ...ously is shown for 5 seconds This key is valid only when this scale has a memorized weight 1 Display Weight Gain Place baby on the baby bas ket for a second time Beep sound 1 Compares a second reading with the first reading eg touse after feeding The incease or decrease is caluculated automatically by pressing weight gain 2 5 seconds Note When checking the weight gain for another baby be sure to m...

Страница 12: ...etting press again Beep sound 4 Auto Power Off Time To complete to set the auto power off time press again Beep sound To save and complete that setting 4 You can set the length of time the weight is displayed after removeing the baby from the scale The Auto Power Off Time setting automatically turns off the power when the scale is unused for the specified length of time s s s s t s Press key Beep ...

Страница 13: ...eader Output data ASCII code Memorized weight XXXXX 3 5 bytes variable length unit g Details 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 LF LF CR CR 8 8 6 6 8 8 3 3 g g R R 4 4 0 0 1 1 g g G G 1 2 3 4 5 6 7 8 9 LF LF CR CR 8 8 6 6 8 8 3 3 g g R R 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 LF LF CR CR 2 2 7 7 9 9 3 3 g g W W 5 5 1...

Страница 14: ...exceeded s P 7 is shown during measure ment Specifications Accuracy at first calibration Model BD 815MA Power Source AC Adapter Centre minus MODEL A30930G CLASS2 Input Voltage 230VAC 50Hz 65mA Output Voltage 9VDC 0 45VDC Rated Current 300mA No Load Voltage 12VDC 0 6VDC Batteries R6 4 Included 6VDC Consumption Current 50mA using the AC Adapter 40mA using the batteries Power Consumption 0 5W max usi...

Страница 15: ...GB 2007 TANITA Corporation All Rights Reserved BD8157021 0 BD815MA GB 07 11 20 11 38 AM 28 ...

Отзывы: