background image

BC-401

Body Composition Monitor

Instruction Manual

Read this Instruction Manual carefully and keep it for future reference.

Images in this manual are for illustration purposes only.

Содержание BC-401

Страница 1: ...BC 401 Body Composition Monitor Instruction Manual Read this Instruction Manual carefully and keep it for future reference Images in this manual are for illustration purposes only ...

Страница 2: ...ing Accurate Readings 7 Initial Setup Type 1 Setup via Smartphone 8 Initial Setup Type 2 from Body Composition Monitor 10 Taking Measurements 11 Setting and Storing Personal Data in Memory 12 Taking Weight and Body Fat Readings 14 Programming the Guest Mode 16 Taking Weight Measurement Only 16 Changing Personal Data 16 Erasing Personal Data 16 Troubleshooting 17 2 ...

Страница 3: ...r on slippery surfaces such as a wet floor Important Notes for Users This Body fat monitor is intended for adults and children ages 5 17 with inactive to moderately active lifestyles and adults with athletic body types Tanita defines athlete as a person involved in intense physical activity of approximately 12 hours per week and who has a resting heart rate of approximately 60 beats per minute or ...

Страница 4: ... or slip resulting in serious injury It may also cause water to get inside the monitor resulting in damage to internal components Interpretation of measurements e g evaluation of measurements and formulation of exercise programmes based on the measurements must be performed by a professional Implementing weight loss measures and exercise programmes based on self analysis could be harmful to your h...

Страница 5: ...ith disabilities who may not be able to take a measurement alone Be sure to insert the batteries with the polarities in the correct position If the batteries are incorrectly inserted battery fluid may leak and damage the floor If you do not intend to use this monitor for a long period of time it is advisable to remove the batteries before storage Do not step on the monitor when your body is wet im...

Страница 6: ...he art technology To keep the unit in the best condition follow these instructions carefully Do not attempt to disassemble the measuring platform Store the unit horizontally and place it so that the buttons will not be pressed accidentally Avoid excessive impact or vibration to the unit Place the unit in an area free from direct sunlight heating equipment high humidity or extreme temperature chang...

Страница 7: ...a period of time Note An accurate reading will not be possible if the soles of your feet are not clean or if your knees are bent or you are in a sitting position The automatic shut down function shuts off the power automatically in the following cases If you interrupt the measurement process The power will shut down automatically within 30 seconds depending upon the type of operation During progra...

Страница 8: ...itial Setup Type 1 Setup via Smartphone If you are not using an app enter settings manually in the Body Composition Monitor P 10 before using If you purchase a new smartphone be sure to adjust the registration of your Body Composition Monitor accordingly Approximate signal range 5 m in areas without obstructions Note Compatible apps may be changed or added in which case screen displays and operati...

Страница 9: ...Composition Monitor is not powered on press and hold the SET button for 3 seconds or more then enter your information as indicated by the app When the Body Composition Monitor is activated is displayed After is displayed carefully step barefoot onto the measuring platform 9 Depending on signal strength it may take a few seconds to connect to the Body Composition Monitor Please refrain from moving ...

Страница 10: ...e same way 3 Set Hour Press the or button to set hour and then press the SET button 4 Set Minute Press the or button to set minute and then press the SET button The device automatically turns off after registered date and time Note 60 seconds or more of inactivity will cause automatic shut off during this process No data will be saved as a result If you make a mistake or wish to turn the unit off ...

Страница 11: ...om your weight is displayed The Smartphone s weight can be entered up to 2 0 kg 4 4 lb 4 lb The maximum weight weighing capacity is reduced by the amount entered for the Smartphone s weight Simply step onto the monitor The auto recognition feature will automatically recall your personal data Your monitor will store up to 10 sets of measurements Saved data is sent to the smartphone together with ne...

Страница 12: ...5 Once you reach the Personal data number you wish to use press the SET button The unit will beep once to confirm Set your Birthday 3 Set the date of your birthday Year Month Day using Who should use Athlete Mode Adults aged 18 years and over who either Train or exercise for 12 hours or more a week and have been doing so for at least six months Are body builders Are professional athletes who want ...

Страница 13: ...n the memory Note If you step onto the scale before appears the display will show and you will not obtain a reading Furthermore if you do not step onto the measuring scale within about 60 seconds after appears the power is shut off automatically Please try the setting and storing personal data process again Specify the Height 5 The display defaults to 170 cm 5 7 0 range of height is from 90 cm 220...

Страница 14: ...ifferent results For advanced scrolling the user may press and hold the button until the required reading is displayed Release the button to view the result and readings will appear for 40 seconds before the unit automatically shuts off Note Do not step off until disappears If the wrong personal number appears on the display You can change the personal number by using the button Press the button u...

Страница 15: ... button to cancel measurement or turn the power off Do not move the monitor for approximately 3 seconds after taking measurements and stepping off To prevent accidents such as falling off the monitor always step off the monitor before operating the buttons Arrows indicate the trend compared to the previous time that a measurement was taken Body Fat Percentage Assessment Muscle Mass Assessment Visc...

Страница 16: ...wn on the display The reading will be shown for 40 seconds When the power is off press the SET button Press the or button to select a personal data number 1 2 3 4 and 5 Once you reach the personal data number you wish to use press the SET button The unit will beep once to confirm Follow the steps as listed on P 12 to change your personal data Changing Personal Data Note If you change the birthday ...

Страница 17: ...sition Monitor will periodically calibrate in preparation for the next weighing If the unit has been stored horizontally with items placed on top or moved from one location to another select your personal data number as explained on p 12 prior to taking your measurement Troubleshooting or appears on the display Are batteries inserted correctly in the Body Composition Monitor Are the batteries runn...

Страница 18: ......

Страница 19: ......

Страница 20: ... 8 lb 0 2 lb Body Fat 5 99 years old 5 99 years old Body Mass Index 18 99 years old Muscle Mass 18 99 years old Physique Rating 18 99 years old Bone Mass 18 99 years old Visceral Fat 18 99 years old Metabolic Age 18 99 years old Total Body Water Personal Data 5 memories Power Supply 4 AAA batteries included Power Consumption 50 mA maximum Measuring Current 50 kHz 6 25 kHz 100 µA Communication Meth...

Отзывы: