![Tanita AP-101 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/tanita/ap-101/ap-101_instruction-manual_817465006.webp)
7
Press “ON/TARE” button again within 10 seconds after pressing the
calibration key. The scale will go into calibration mode.
Note:
If “ON/TARE” button is not pressed within 10 seconds, the scale will turn off
automatically.
8
The LCD display will start showing some range of various numbers.
It will display “0000” with stabilize (
°
) mark on the left top corner.
9
Place 50g on the center of the platform within 15 seconds.
10
The display will show “0001” >>>”0004 and stabilize (
°
) mark, then
place an addition 50g within 15 seconds. (The total weight on the
platform is 100g)
11
The display will show “0005” >>> “0.000”, then you can remove the
weights. The display will go to 0.0 and stabilize (
°
) mark.
12
Turn scale off. The calibration procedure is complete.
Note:
・
When calibrating the scale, please pay close attention to the environment around you.
When doing the adjustments, please place the scale where there are no vibrations, wind,
temperature deviation, etc.
・
“Err 4” appears on the display during calibration mode.
Please place weight(s) within 15 seconds.
Please make sure the scale is stable.
GB/USA
08
Calibration Instruction
07
GB/USA
Aluminum plate
Calibration
switch
1
Scale must be on a level working area.
2
Remove the battery cover and detach the
aluminum plate near the batteries. The
calibration switch is underneath this plate.
3
Press “ON/TARE” button.
4
Wait for “0.0” to be displayed.
5
Using the extra foot or a pin, press and
hold the base calibration switch for 2
seconds. Release the base calibration
switch. The display will show “CAL”.
Note:
Do not put any stress on top platform when
you are calibrating the scale.
6
Immediately place the scale gently on a
level surface.
Before calibrating you must have two 50 gram certified weights
and the extra foot that was provided or a small pin.
Please read the calibration instruction
very carefully.
(This instruction is only for authorized personnel)
AP101取説 06.7.24 3:09 PM ページ11