• Machine transport, handling and storage personnel must be adequately instructed and

trained regarding the use of lifting systems and personal protection equipment suitable
for the type of operation carried out.

A.5

Installation and assembly

• The appliance is only to be installed in locations where its use and maintenance is

restricted to trained personnel.

• Follow the installation instruction supplied with the appliance.
• Do not install a damaged appliance. Any missing or faulty parts must be replaced with

original parts.

• Do not make any modifications to the parts supplied with the appliance.
• Disconnect the appliance from the power supply before carrying out any installation

procedure. Connect the appliance to the power supply only at the end of the installation.

• The appliance is not suitable for installation outdoors and/or in places exposed to

atmospheric agents (rain, direct sunlight, freeze, humid, water jet or slashing and dusty
location, etc.).

• The appliance is not suitable for installation in an area where a water jet could be used.
• The floor where you install the appliance has to be a horizontal plane, stable, heat

resistant and clean.

• Access to the service area is limited to persons with the necessary knowledge of safety

and hygiene as well as practical experience of the device.

• Leave enough free space around the appliance to facilitate its use and to preform any

maintenance operations.

• Before connecting the power and water supplies, check that the electrical and water

network are in accordance with the technical information plate of the device.

A.6

Water connection

• The plumbing connections must be carried out by a specialised personnel.
• The machine is to be connected to the water mains using the new supplied hose-sets.

Do not use old hose sets.

• Always use a new set of joints if you remove and re-install the water inlet pipe to the

machine.

Before connection to new pipes, pipes not used for a long time, where repair work has

been carried out or new devices fitted (water meters, etc.), let the water flow until it is
clean and clear.

• The appliance must be install with a new softener.
• The dynamic water pressure (minimum and maximum) must be between:

– 1 bar [0.1 MPa] and 10 bar [1 MPa];

• Make sure that there are no visible water leaks during and after the first use of the

machine.

• Install an approved dual check valve upstream according to the regulation of the

installation country.

• At the end of the service or in case of prolonged absence cut off the water by the general

tap.

A.7

Electrical connection

• Do not disconnect or modify the security elements in the appliance, the manufacturer is

not responsible for the consequences of an inadequate using system.

• Work on the electrical systems must only be carried out by a specialised personnel.
• Make sure that the electrical information on the rating plate agrees with the power supply.

Содержание DUO XP

Страница 1: ...TANGO DUO XP EN User manual Original instructions NA9220 2023 06...

Страница 2: ...2 Installation diagram 492 79 mini 199 max 335 344 73 154 50 mini 50 mini 810 817 643 72 79 624 327 80 300 mini 50 mini 173 49 109 246 94 53 EI CW DO EQ...

Страница 3: ...3 DO Drain outlet EI Electricity inlet EQ Equipotential screw CWI Cold water inlet 3 8...

Страница 4: ...ts use and maintenance The manual must be available to operators and carefully kept in the place where the appliance is used so that it is always at hand for consultation in case of doubts or whenever...

Страница 5: ...Residual risks 11 C GENERAL INFORMATION 12 C 1 Introduction 12 C 2 Definitions 12 C 3 Machine and manufacturer s identification data 12 C 4 Responsibility 13 C 5 Copyright 13 C 6 Keeping the manual 1...

Страница 6: ...m children Cleaning and user maintenance shall not be made by children without supervision This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory...

Страница 7: ...to health depending on the model 2 During these operations gloves must be suitable for contact with chemical substances used refer to the safety data sheet of the substances used for information regar...

Страница 8: ...nd the appliance to facilitate its use and to preform any maintenance operations Before connecting the power and water supplies check that the electrical and water network are in accordance with the t...

Страница 9: ...n current e g 30 mA coordinated with the earthing system of the building where the appliance is located must be installed ahead of the supply The power supply must be provided with the following safet...

Страница 10: ...and gloves tools and ancillary means Do not clean the appliance with jets of water Repair and extraordinary maintenance Repair and extraordinary maintenance have to be carried out by specialised autho...

Страница 11: ...ed out according to the instructions given in this manual Make sure to periodically check correct operation of all the safety devices and the insulation of electrical cables which must be replaced if...

Страница 12: ...is advisable to read them carefully before use Operator machine installation adjustment use maintenance cleaning repair and trans port personnel Manufacturer Electrolux Professionnel SAS or any other...

Страница 13: ...supplements to the installation use and maintenance manual the Customer receives from the Manufacturer will form an integral part of the manual and therefore must be kept together with it C 5 Copyrigh...

Страница 14: ...installed and the hydraulic electrical connections have been carried out by a qualified installer G 1 Switching on Set the main switch on position 1 The touch screen illuminates and appears thus The b...

Страница 15: ...right mill 6 Icon to access the error codes alarms activated 7 To access to different profiles 8 To choose the language 9 Scrolls the product keyboards 10 Steam icon Initiate the production of steam G...

Страница 16: ...the machine Steam nozzle After every use clean the steam tube with a damp cloth and press the steam key briefly to drive out the small amount of liquid e g milk remaining in the tube Remove the tip o...

Страница 17: ...ar even if it does not reach the end of its filtering capacity I 4 Machine disposal At the end of the product s life cycle make sure the equipment is not dispersed in the environment The equipment mus...

Страница 18: ......

Страница 19: ......

Страница 20: ...Electrolux Professionel SAS Usine de Carros Z I 4 me rue 06510 CARROS France T l 33 04 92 08 62 60 Fax 33 04 93 29 24 23 info unic electroluxprofessional com...