8
General Instructions
PROBLEM
No Water When Activated
Red LED in electronic eye
POSSIBLE CAUSE/SOLUTION
If red LED stays on or is fl ashing:
1. Replace batteries.
2. If appropriate action from no. 1 does
not correct problem, the sensor range is
too long/picking up sink; reduce range.
Otherwise sensor is faulty; contact
dealer.
1. Check supply stop(s); open if closed.
2. Debris in supply hose fi lter washers;
remove, clean and reinstall.
3. Debris in aerator or spray head;
remove, clean and reinstall
1. Check surroundings for factors
that can contribute to the range; for
example, bright lights, highly refl ective
surfaces, sunlight, etc.
2. Range too long; decrease sensor
range.
1. Debris in solenoid valve, won’t close
properly. Contact factory.
Very Low Flow or Slow Dribble
False Triggering
(Unit goes on by itself )
Continues to Run
(Even after power to faucet has been
reconnected)
TROUBLESHOOTING GUIDE