25
5.
PERFORMANCE SPECIFICATION
Insulation resistance at 1000V DC:
Not less than 10 megohms between mains input to frame
Applied voltage test
:
2.0kV rms for 1 minute between mains input and frame
Induced voltage test:
± 35kV DC for 5 minutes
Flashover test:
6 flashovers at 30kV DC on each output direct to earth
Normal voltage test:
± 30kV DC on no load for 30 minutes
Accuracy of instruments:
Output kV meters ± 1.5% at full scale
Output mA meters ± 2.5% at full scale on each range
Содержание PT30-10 mk2
Страница 2: ...2...
Страница 6: ...6...
Страница 8: ...8 5 PERFORMANCE SPECIFICATION 25 6 REVISION 27...
Страница 22: ...22...
Страница 24: ...24...
Страница 26: ...26...
Страница 28: ...28 Drawings Required A2 001344 latest issue...