1.3
Electrical Specification
1.3.1
Supply Requirements
The PCU1 systems require a single phase 50/60Hz supply of 230V±10%. The maximum
power requirement of the system depends on the level of current to be drawn from the control
unit. For maximum output a 50A supply is required, but in most situations a 32A supply will
suffice.
Loading unit
Open Circuit
Voltage
Load current
Max time for
load current
Supply
current
NLU5000
2.3V
3000A
5 minutes
30A
5000A
40 seconds
50A
4.6V
1500A
5 minutes
30A
2500A
40 seconds
50A
9.2V
750A
5 minutes
30A
1250A
40 seconds
50A
NLU2000
3.5V
1200A
5 minutes
18A
2000A
40 seconds
30A
6.9V
600A
5 minutes
18A
1000A
40 seconds
30A
13.8V
300A
5 minutes
18A
500A
40 seconds
30A
NLU200
60V
80A
5 minutes
21A
200A
40 seconds
50A
120V
40A
5 minutes
21A
100A
40 seconds
50A
Overload ratings are also available when operating in pulse mode. In this mode the output
current (and therefore supply current) may be higher for a maximum of two seconds. In every
case the maximum achievable output current is defined by the output cable and load
impedance.