HOLE
Fig #20
Fig #21
Minimum
rate screw
5.
With a ½” wrench remove the natural gas
orifi ce (#32) and replace with propane
orifi ce (#48)(our part # 5021.3407)
(Fig.
#17)
6.
Fully open the primary air shutter.
7.
Reinstall the manifold and air defl ector
8.
With a 7/16” wrench loosen the pilot head
on the pilot assembly by a half-turn
(Fig.
#20)
9.
Slide the pilot adjustment band over and
ensure that the hole in the orifi ce band
is showing. (Fig. #21 shows NG position,
Fig. # 22 shows LP position)
Retighten pilot head.
10. Remove right hand brick panel (if
installed) and access panel located on
right hand side of fi rebox
(See Fig. #27).
11.
Remove the minimum rate screw located
in the valve.
(Fig.
#23)
NOTE: Primary air shutter must
be fully closed for Natural gas or
fully open for Propane.
Fig #18
Fig #19
Fig #22
Fig #23
Fig #17
10
TC30.NG06C 200411-16