![TANDBERG T2000 MXP Скачать руководство пользователя страница 243](http://html1.mh-extra.com/html/tandberg/t2000-mxp/t2000-mxp_user-manual_3500772243.webp)
Appendices
233
Function
Port
Type
Gatekeeper Discovery (RAS)
1719
UDP
Q.931 Call Setup
1720
TCP
H.245*
Range 5555-5565
TCP
Video
Range 2326-2405
UDP
Audio
Range 2326-2405
UDP
Data/FECC
Range 2326-2405
UDP
(*) Note: While using MultiSite, if a site is disconnected and reconnected without terminating the
entire conference, the next site to be connected will have a H.245 port outside of the specified
range. If this functionality is required through a firewall, the range of TCP ports can be extended
past 5564. However, if a site is disconnected and reconnected, without ending the conference
enough times one can quickly end up outside of this range again.