Administrator Settings
147
- as making 2 x 64 kbps or 2 x 56 kbps calls to the same system.
Place this type of call by:
Set Network to ISDN
Set Bandwidth to 128 kbps
A field for the 2nd number pops up in Call Settings.
Enter the second number in the Call Settings field. For 128 kbps calls that use bonding,
ignore the second number field and just enter one number to be dialed.
Using sub-address / extension address / MCU password
Sub-address is used to address different systems on the same ISDN line and is primarily used in
European Countries. LAN equivalent extension address or TCS-4 is used to address different
systems on a LAN, when dialing via a gateway.
To specify an ISDN sub-address or its LAN equivalent extension address (TCS-4), add a star (*)
after the number and then enter the sub-address/extension address.
Example:
12345678*10 ( <number>*<Sub-address/extension address/MCU password>)
When dialing IP via a gateway, the number behind the star (*) on IP might be interpreted as an
extension address.
When calling to external MCU
’
s requiring a password (TSC-1), this password can be added after
the star (*). If no password is specified, the user will be asked to enter the password (after
connecting to the MCU).
Содержание T2000 MXP
Страница 10: ......
Страница 17: ...Introduction 7...
Страница 19: ...Installation 9 2 1 Mounting When mounting the TANDBERG 2000 MXP follow the figures below...
Страница 44: ...D1337703_T2000_MXP_User_Manual 34...
Страница 55: ...General Use 45 Call History My Contacts Global Contacts...
Страница 172: ...D1337703_T2000_MXP_User_Manual 162 Voice Switched mode...
Страница 174: ...D1337703_T2000_MXP_User_Manual 164 4 7 Security Security contains the settings Encryption Encryption Mode Passwords...
Страница 215: ...Peripheral Equipment 205 5 9 Dual Monitor Note that this requires a system with dual monitor video output...
Страница 250: ......