Tandberg Data
SCSI Commands
______________________________________________________________________
2-54
Tandberg SLR Autoloader SCSI Functional Specifications
Vendor Unique
The vendor unique field shall be set to 00b to perform the firmware
download operation. Non-zero values in this field are intended for factory
use only.
CAUTION!
Using non-zero values in the vendor unique field may cause unpredictable
results and the medium changer device may become unusable.
NOTE:
If an error occurs during the firmware download process after the first 64K bytes of
data have been transferred, the flash firmware may become unusable and it may not
be possible to complete a firmware upgrade using the SCSI WRITE BUFFER
command. If this occurs, the only recovery action is to update the firmware using the
serial port on the library. Refer to the Installation and User Manual for additional
information on Installing Firmware Upgrades using the serial port.