CHAPTER 6: SCSI and Controller Interface Specification
6.2
Setting the SCSI ID
Each device on the SCSI bus must have a unique SCSI ID address assigned to it.
For specific recommendations for assigning SCSI IDs, refer to the system or SCSI
controller documentation.
Internal drives can be configured for SCSI ID addresses that range from 0 to 15 in
one of two ways:
•
Jumper the 10-pin SCSI ID block located on the back of the drive (
Figure 6-1
on page 6-4
), OR
•
In a library setting, you can set the IDs through firmware. (The firmware
default = SCSI ID 5 and assumes no jumpers are installed on the jumper
block.)
N
OTE
: The default setting for the tape drive is 5; the host adapter
setting is typically SCSI ID 7. If you choose to omit all
jumpers from the SCSI ID block, the tape drive will use
the default setting of 5.
This section discusses setting the SCSI ID on the internal drive via the jumper
block.
Table 6-1
lists the SCSI ID address and jumper settings.