CHAPTER 2: General Drive Specifications
2.7.1 Temperature and Humidity
The ambient operating environment for the tape drive may not exceed the limits
shown in
Table 2-11
. (The specifications shown in the table are valid for both the
internal and tabletop tape drives.)
2.7.2 Air Flow Requirements
Adequate air flow must be provided for the internal unit to dissipate the heat
resulting from drive operation (see
CHAPTER 4, “Thermal Specifications”
for
more details about temperatures inside the drive, and illustrations showing where
air flow and various temperatures are measured). The air flow must be sufficient to
keep the tape path temperature below 52°C.
N
OTE
: It is important to realize that the amount of air flow
provided for the tape drive determines the maximum
ambient temperature in which the drive can operate.
Table 2-11.
Temperature and Humidity Specification
Specification
Operating Limits
Non-Operating Limits
(Power On; No Tape
Loaded)
Wet Bulb Temperature
25°C (77°F)
25°C (77°F)
Dry Bulb Temperature
Range
10
°
C to 40
°
C (50
°
F to 104
°
F)
10
°
C to 40
°
C (50
°
F to 104
°
F)
Temperature Gradient
11
°
C (20°F) / hour (across range)
15
°
C (27°F) / hour (across range)
Relative Humidity
20% to 80% (non-condensing)
10% to 90% (non-condensing)
Humidity Gradient
10% / hour
10% / hour
Содержание SDLT220-320 INTEGRATION
Страница 1: ...TANDBERG Super DLTTM Design Intergration Guide Revision 1 June 2002 432588 01...
Страница 4: ...SDLT 220 and SDLT 320 Design Integration Guide...
Страница 18: ...CHAPTER 1 Introduction...
Страница 24: ...CHAPTER 2 General Drive Specifications Figure 2 6 Front Views of SDLT 220 320 Tape Drive...
Страница 53: ...CHAPTER 4 Thermal Specifications Figure 4 3 HIM Board Thermal Measurement Location Qlogic...
Страница 80: ...CHAPTER 6 SCSI and Controller Interface Specification...
Страница 86: ...CHAPTER 7 Updating the Firmware...
Страница 93: ......