Functional Specifications
SDLT 600 Product Manual
3-12
March 2004
81-81184-02 REV A01
Table 3-16.
Current and Power Requirements (SCSI Interface)
Mode
5 V Current (A)
MaxPk
1
MaxMean
2
Typ
3
12 V Current (A)
MaxPk
1
MaxMean
2
Typ
3
DC Power (W)
Max
4
Typ
5
AC Power (W)
Max
6
Typ
7
Standby/Idle
2.6
2.6
2.4
0.2
0.1
0.1
14
14
47
45
Media Loading/
Unloading
6.2
5.3
3.4
2.7
0.9
0.7
30
26
64
56
600 Write–
Motor Start
8
4.3
4.0
3.7
1.3
0.3
0.3
23
22
51
48
600 Write–
Streaming
5.4
5.1
4.9
0.7
0.5
0.4
30
30
65
63
Max for
SDLT 600 tape
drive Modes
9
n/a
5.3
n/a
n/a
0.9
n/a
30
n/a
70
n/a
1. The Max-Peak value represents short current spikes drawn for durations of < 50
m
s. On the 12V supply, the peaks
correspond to the pulse-width-modulated switching of the motors. These values are calculated from the average of
Peak-ripple-c 2 sigma, measured at nominal DC voltage.
2. The Max-Mean value is the average of the maximum RMS current drawn during this operating mode. These
values are calculated from the average of RMS c 3 sigma, measured at nominal DC voltage.
3. The typical current is calculated from the average of all RMS current drawn during this operating mode, measured
at nominal DC voltage.
4. The Max DC power is calculated from the typical DC power + 3 sigma, measured at nominal DC voltage. This
value takes into account that the peak currents on the 5V and 12V do not occur at the same time.
5. The Typical DC power is calculated from the average RMS DC power drawn during this operating mode,
measured at nominal DC voltage. This value also takes into account that the peak currents on the 5V and 12V do
not occur at the same time.
6. The Max AC power is calculated from the typical AC power in tabletop tape 3 sigma.
7. The Typical AC power is calculated from the average of AC power drawn in tabletop tape drives.
8. These events last < 1 second and occur at a duty cycle of less than 25%.
9. The Max values for each mode are based on the Max-Mean values, since the peak values are of very short
duration.
(Common Notes)
(1) Voltage tolerance: 5V ±5%, 12V ±5%; Room temperature 24 °C. AC power measured at 117 V, 60 Hz.
(2) DC Current, MaxMean, and DC/AC Power Max refer to the statistically calculated maximum average
requirement based on a sample population of tape drives. These values do not reflect the peak current or power
requirement; this amount is given by the DC MaxPk current.
Содержание SDLT 600
Страница 1: ...SDLT 600 Product Manual...
Страница 6: ...SDLT 600 Product Manual vi...
Страница 48: ...Recording Media Specifications SDLT 600 Product Manual 3 20 March 2004 81 81184 02 REV A01...
Страница 74: ...Confirming the Installation SDLT 600 Product Manual 4 26 March 2004 81 81184 02 REV A01...
Страница 112: ...Unloading a Data Cartridge SDLT 600 Product Manual B 10 March 2004 81 81184 02 REV A01...
Страница 124: ...X SDLT 600 Product Manual G 12 March 2004 81 81184 02 REV A01...
Страница 125: ......