2 Installation   

 

2.1 Installation Preparation 

This alarm warning device must be installed, commissioned and maintained by a qualified or factory 
trained service personnel. The installation must be installed in compliance with all local codes having 
a jurisdiction in your area or BS 5839 Part 1 and EN54. 

2.2 Installation and Wiring 

1.

 

Mount  the  sounder  base  on  standard  one  [1]  gang  electrical  back  box.  Follow  the  arrow 
mark for the correct position. Do not over-tighten the screws otherwise the base will twist. Use 
M4 standard screws.  

2.

 

Connect  the  wire  in  terminal  as  shown  in  Figure  [2&3].  Verify  the  device  number  or  other 
device  parameters  if  desired  using  handheld  programmer  then  stick  on  the  label  before 
attaching sounder.  The sticker labels are available on the control panel.  

3.

 

Attach the sounder to the base, point the sounder in the base by the mark-line and secure 
the sounder in that position by rotating it clockwise, until it reaches the next mark line.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2: Loop Powered  

 

Figure 1  

 

Figure 3:  With External Supply  

 

Terminal Description  

1

 

Signal In (+) 

2

 

Signal Out (+) 

3

 

External PSU In (+) Optional 

4

 

External PSU Out (+)Optional 

5

 

Signal In (-) 

6

 

Signal Out (-) 

7

 

External PSU In(-)Optional 

8

 

External PSU Out (-)Optional 

 

 

 

 

Содержание TX7320

Страница 1: ...TX7320 Addressable Sounder Installation and Operation Manual TANDA UK Technology Copyright 2015 All right reserved...

Страница 2: ...nstalling the Sounder to ensure proper and safe operation of the system European Union directive 2012 19 EU WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal...

Страница 3: ...pecification 4 2 Installation 5 2 1 Installation Preparation 5 2 2 Installation and Wiring 5 3 Sounder Configuration 6 3 1 Preparation 6 3 2 Addressing 6 3 3 Single and Dual Address Mode 7 3 4 Typical...

Страница 4: ...ntelligent Fire Alarm Control Panel produced by single manufacture T A to avoid addressable communication compatibility problem 1 2 Feature and Benefits EN54 3 Compliance Built in MCU processor and di...

Страница 5: ...he correct position Do not over tighten the screws otherwise the base will twist Use M4 standard screws 2 Connect the wire in terminal as shown in Figure 2 3 Verify the device number or other device p...

Страница 6: ...ts Program a unique address number for each device according to the project layout before placing from the Terminal Base Warning Disconnect the loop connection whilst connecting to the handheld progra...

Страница 7: ...will produce simultaneously audible signal according to the pre defined tone Table 1 Tone 14 is the default tone and will stop if the panel is reset 1 Attach the programming cable to 1 and 6 Terminals...

Страница 8: ...11 Note If display Success means the entered mode is confirmed If display Fail means failure to program the mode Warning Under saving mode loop powered up to 20 sounder maximum per loop is the recomme...

Страница 9: ...3 3 5s on 0 5s off 7 07 106 6 101 4 2850Hz 0 5s on 0 5s off 3 1 5s off 8 08 106 1 102 3 2850Hz 0 4s on 0 3s off 9 09 99 7 96 6 550Hz 0 7s 1000Hz 0 33s 10 10 105 7 100 8 1500Hz 2700Hz 3Hz 11 11 102 3 9...

Страница 10: ...f display Fail means failure to program the tone Figure16 Tone 14 Tone 16 and Tone 17 are recognized by LPCB 3 Press Exit key to go back Main Menu Press Power to switch off the programmer 3 7 Read Con...

Страница 11: ...running 6 Perform the maintenance on semi annually or depending on the site conditions 5 Troubleshooting Guide What you notice What it means What to do Address not enrolling The wiring is loose The a...

Страница 12: ...27 5V Min 18V 15 87 3 85 1 89 3 98 0 76 7 76 1 76 1 77 3 45 87 3 83 9 86 7 84 4 75 4 76 8 81 0 81 2 75 84 2 81 1 94 3 90 9 81 9 83 7 81 4 82 8 105 84 1 82 4 90 9 87 7 79 5 81 2 79 4 80 2 135 89 7 87 6...

Отзывы: