Introduction

The TAMS HP-IB Interface is intended to add IEEE-488 capabilities to any computer
with a PCI bus.

The TAMS card takes full advantage of the PCI bus performance and delivers the
highest possible level of throughput.

The TAMS Interface supports both the 3.3v and 5v PCI specifications as a universal
card.

Thanks to HP’s software architecture and the design of the TAMS driver, once the
driver is loaded (which is done once at installation) the TAMS card can be used in any
application without requiring more computer overhead or any changes to code
developed for HP’s HP-IB cards.

Whether you are using HP-VEE, HPBASIC/UX, or programming in C with the TAMS I/O
Libraries, your code will now run at full performance without modification.

Hardware Warranty

All TAMS products use the highest quality components and are assembled to the
highest specifications.  Should a defect exist, or a failure occur, we apologize. Any
defective unit will be repaired or replaced immediately.

Please follow the instructions below for service response.

•     

  In the US please return it to TAMS. Please call or fax for return instructions.

      Internationally, please contact the local distributor for return instructions.

Any customer may contact TAMS, or return products directly to TAMS, but for
customers outside the US, this may cause a delay, which could be avoided by working
with the local distributor.

The complete hardware warranty information is in Appendix C.

For software warranty information see the Software License in Appendix B.

Содержание 81488

Страница 1: ...TAMS 81488 HP IB Card for Linux Installation Operation...

Страница 2: ...nstallation Operation Test Measurement Systems Inc 750 14th Street SW Loveland Colorado 80537 USA Telephone 970 669 6553 Fax 970 669 3090 Web Site www tamsinc com Email info tamsinc com Copyright Test...

Страница 3: ...Equivalent Loads 6 Installing the HP IB Interface 7 Connecting the HP IB Cable 8 Installing the Software 9 Configuring the Card 11 Configuring the Card Using iosetup 11 Configuring the Card Manually...

Страница 4: ...h the TAMS I O Libraries your code will now run at full performance without modification Hardware Warranty All TAMS products use the highest quality components and are assembled to the highest specifi...

Страница 5: ...ng an interface with the power on can damage the interface and the computer Most interfaces contain components that are sensitive to damage from electrostatic discharge Use protective measures includi...

Страница 6: ...rs are installed If your bus system will have more than nine additional devices carefully remove both of the resistor packs and store them If the resistors need to be reinstalled later on be sure that...

Страница 7: ...nstructions on opening your computer and installing PCI boards Follow the instructions being careful to handle the TAMS interface board only by its edges After the board has been plugged in and the re...

Страница 8: ...nfiguration and so the standard connector on the cable supplied can be attached directly to any HP IB device or to any device in a chain of HP IB devices The following illustrations show correct conne...

Страница 9: ...Change to the directory where the driver is cd mnt cdrom 81488 5 Use RPM to install the driver Architecture specific versions of the software have been provided for systems running the supported kerne...

Страница 10: ...he necessary directories by default Appendix Ais a reference for the Linux systems administrator who might wish to know where these files are placed You will still need to configure the new TAMS HP IB...

Страница 11: ...ntly configured under SICL 3 Rotary Switch the user must specify the setting of the rotary DIP switch on the card 4 HP IB Address the user must specify the HP IB bus address that the TAMS card is to u...

Страница 12: ...vice In a system configuration the total device capacitance should be no more than 50pF for each equivalent resistive load in the system d All devices in the system should be powered on e Interconnect...

Страница 13: ...se on the HP IB bus This value must not be the same as any other device connected to the HP IB cable It may be the same as other HP IB interface cards in the computer so long as those other cards are...

Страница 14: ...d be no more than 50pF for each equivalent resistive load in the system d All devices in the system should be powered on e Interconnecting cable links should be as short as possible up to a maximum of...

Страница 15: ...1488 o lib modules kernel version kernel drivers char kernel driver module t81488 etc init d start stop scripts for un loading the kernel module and un creating the device files S95t81488 K05t81488 et...

Страница 16: ...t or violation of this License Agreement TRANSFER OF RIGHTS IN SOFTWARE Customer may transfer rights in the software to a third party only as part of the transfer of all their rights and only if Custo...

Страница 17: ...able amount of time Customer s alternate remedy shall be a refund of the purchase price upon return of the entire product and all copies NOTICE OF WARRANTY CLAIMS Customer must notify TAMS in writing...

Страница 18: ...gives you specific legal rights and you may also have other rights which vary from state to state and from country to country This Warranty is in Lieu of all other express warranties which now or her...

Страница 19: ...19 This page left intentionally blank...

Страница 20: ...TAMS 81488 HP IB Card for Red Hat Linux Printed in USA E04 01 04 Part 81488 90001...

Отзывы: