tams elektronik WIB-33.2 Скачать руководство пользователя страница 21

tams 

elektronik

WIB-33.2 

English

11. Guarantee bond

For this product we issue voluntarily a guarantee of 2 years from the
date of purchase by the first customer, but in maximum 3 years after
the end of series production. The first customer is the consumer first
purchasing the product from us, a dealer or another natural or juristic
person   reselling   or   mounting   the   product   on   the   basis   of   self-
employment. The guarantee exists supplementary to the legal warranty
of merchantability due to the consumer by the seller.
The warranty includes the free correction of faults which can be proved
to be due to material failure or factory flaw. With kits we   guarantee
the completeness and quality of the components as well as the function
of the parts according  to the parameters in not mounted state. We
guarantee the adherence to the technical specifications when the kit
has been assembled and the ready-built circuit  connected according to
the   manual     and   when   start   and   mode   of   operation   follow   the
instructions.
We retain the right to repair, make improvements, to deliver spares or
to  return   the   purchase   price.   Other  claims   are   excluded.   Claims   for
secondary damages or product liability consist only according to legal
requirements.
Condition   for   this   guarantee   to   be   valid,   is   the   adherence   to   the
manual. In addition, the guarantee claim is excluded in the following
cases:

if arbitrary changes in the circuit are made,

if repair attempts have failed with a ready-built module or device,

if damaged by other persons,

if damaged by faulty operation or by careless use or abuse.

12.  EU declaration of conformity

This product conforms with the EC-directives mentioned below
and is therefore CE certified. 

2004/108/EG  on  electromagnetic.   Underlying   standards:  EN  55014-1
and   EN   61000-6-3.   To   guarantee   the   electromagnetic   tolerance   in
operation you must take the following precautions:

Connect the transformer only to an approved mains socket installed
by an authorised electrician.

Make   no  changes   to  the   original   parts   and   accurately   follow   the
instructions, connection diagrams and PCB layout included with this
manual.

Use only original spare parts for repairs.

2011/65/EG   on   the   restriction   of   the   use   of   certain   hazardous
substances in electrical and electronic equipment (ROHS).  Underlying
standard: EN 50581.

13. Declarations conforming to the WEEE directive

This product conforms with the EC-directive 2012/19/EG on
waste electrical and electronic equipment (WEEE).

Don´t dispose of this product in the house refuse, bring it to the next
recycling bay. 

Page 21

Содержание WIB-33.2

Страница 1: ...a m s e l e k t r o n i k Manual WIB 33 2 Carriage lighting with integrated function decoder Colour of lighting warm white Item no 53 01340 tams elektronik n n n Version 2016 with OSRAM LEDs Duris E5...

Страница 2: ...13 8 Configuration variables and registers 14 9 Presets 19 10 Check list for troubleshooting 20 11 Guarantee bond 21 12 EU declaration of conformity 21 13 Declarations conforming to the WEEE directiv...

Страница 3: ...o static electricity Do not touch components without first discharging yourself Touching a radiator or other grounded metal part will discharge you Checking the package contents Please make sure that...

Страница 4: ...ing iron can cause fire which can result in injury or death through burns or suffocation Connect your soldering iron or soldering station only when actually needed Always keep the soldering iron away...

Страница 5: ...e soldering tip to the soldering spot in such a way that the wire and the soldering eye are heated at the same time Simultaneously add solder not too much As soon as the solder becomes liquid take it...

Страница 6: ...ogue carriage lighting WIB 13 2 is suitable especially for combining with the lighting of the 30s series in a block train Driving in digital Operation There is a function decoder integrated on the PCB...

Страница 7: ...all LEDs Activating the addtional function outputs There are three outputs for external loads on the PCB controlled by the integrated decoder The output AUX2 is designed for the connection of LEDs fo...

Страница 8: ...It allows e g the feedback of the address and the CV values from the decoder to the digital control unit or to special receivers so called detectors The decoders must be designed to send the RailCom m...

Страница 9: ...of the function outputs AUX 1 and 3 AUX 2 300 mA each 20 mA Connection for bridging capacitor gold cap for the supply of the LEDs 1 electrolytic capacitor 100 F 16 V or gold cap 5 5 V Connection for...

Страница 10: ...LED8 with separate connection of section 2 RL3 return conductor for L4 L8 Shortening the carriage lighting You can divide or shorten the print at the marked spots Caution Pay attention not to damage t...

Страница 11: ...voltage sustaining capability of 16 V or two goldcaps with a voltage sustaining capability of 5 5 V Solder them to the connecting points E1 and E1 Loads connected to the outputs of the integrated func...

Страница 12: ...side of the accessory to the return conductor of the decoder point RL1 Caution If you connect the accessories to the return conductor for all functions point RL1 the accessories must be insulated The...

Страница 13: ...it for both DCC and Motorola format it is recommended to program the decoder in the DCC format After having finished programming the decoder it is possible to control it in Motorola format as well Put...

Страница 14: ...you do not want to program all configuration variables or registers individually you can fall back on different presets see CV 130 and section 9 Please note With variables destined to set several para...

Страница 15: ...6 Direction Standard 28 or 128 speed levels in DCC mode RailCom on Automatic analogue recognition on Extended Addresses Tip If the use of extended addresses is activated in CV 29 the decoder does not...

Страница 16: ...hing the 8 LEDs Name of CVs Registers CV no Reg no Input value Default Remarks and Tips Settings F0 forward on 33 11 0 255 0 LED 1 1 F0 backward on 34 12 0 255 0 LED 2 2 F1 35 13 0 255 170 LED 3 4 F2...

Страница 17: ...nd 15 for each output Enter the value directly for the odd LEDs and outputs for the even LEDs and outputs multiply the value by 16 Example For LED1 value 14 and for LED2 value 2 Input value in CV 59 1...

Страница 18: ...55 35 short flickering 1 LED5 LED6 128 50 0 255 83 LED7 LED8 129 51 0 255 71 long flickering 15 You can choose a value between 0 and 15 for each output Enter the value directly for the even LEDs for t...

Страница 19: ...es Control units with few function keys Control units with few function keys Switching the LEDs F1 1st half of LEDs F2 2nd half of LEDs F1 all LEDs Dim switch to be switched with F4 to be switched wit...

Страница 20: ...eck the connection of the module Possible cause The dim switch is activated and the limit value is set the wrong way Check the settings in CV 112 CV 113 and CV 115 You cannot switch an output Possible...

Страница 21: ...product liability consist only according to legal requirements Condition for this guarantee to be valid is the adherence to the manual In addition the guarantee claim is excluded in the following case...

Страница 22: ...t a m s e l e k t r o n i k English WIB 33 2 Page 22...

Страница 23: ...t a m s e l e k t r o n i k WIB 33 2 English Page 23...

Страница 24: ...tions et conseils Actuele informatie en tips n n http www tams online de n n n Garantie und Service Warranty and service Garantie et service Garantie en service n n Tams Elektronik GmbH n Fuhrberger S...

Отзывы: