8. Connecting the MT-1
Follow the connections diagrams fig. MT-1.1 and MT-1.2 and connect
the minitimer MT-1 as follows:
X1
device
(polarized device "-")
X2
device
(polarized device "+")
X3
transformer
(with direct voltage "+")
X4
transformer
(with direct voltage "
^
")
X5
X6
switching input
In order to trigger the minitimer MT-1 the switching input (connections
X5 and X6) has to be shunted, e.g. with a key switch. Then, the
connected device will be switched on for a time between 1 and 100
seconds and be switched off after this time.
Caution:
The power consumption of the connected device may not exceed
100 mA, otherwise the module will be destroyed. Devices with a
higher power consumption can be switched via a relay.
Setting the switching time
Set the desired switching time at the trimm pot R8. It is between 1 and
100 seconds (+ 20 %), depending on the settings. With some mounting
situations it makes sense to set the switching time while performing a
functional test with a lamp.
Connecting a relay
In order to switch a device with more than 100 mA power consumption
or to switch off a device you have to connect the device via a relay
(12 V). In order to switch over between two devices you will need a
relay (12 V).
Seite 23
Содержание MT-1
Страница 24: ...t a m s e l e k t r o n i k English MT 1 MT 2 MT 3 Fig MT 1 1 MT 1 Connections Seite 24...
Страница 25: ...t a m s e l e k t r o n i k MT 1 MT 2 MT 3 English Fig MT 1 2 MT 1 Connection of a device via a relay Seite 25...
Страница 27: ...t a m s e l e k t r o n i k MT 1 MT 2 MT 3 English Fig MT 2 1 MT 2 Connections Seite 27...
Страница 28: ...t a m s e l e k t r o n i k English MT 1 MT 2 MT 3 Fig MT 2 2 MT 2 Connection of a device via a relay Seite 28...
Страница 30: ...t a m s e l e k t r o n i k English MT 1 MT 2 MT 3 Fig MT 3 1 MT 3 Connections Seite 30...
Страница 31: ...t a m s e l e k t r o n i k MT 1 MT 2 MT 3 English Fig MT 3 2 MT 3 Connection of a device via a relay Seite 31...