48
51
0 ... 255
Voltage at
extended kick
function
(0)
= voltage applied to the
motor when switching an
output via the extended kick
function.
Konfigurations- 49
22
0 ... 127
Numerical value
*
daten 2
(73)
Load control inactive
0
Load control active
(LD-G-33 only)
1
Shunting gear at F1
2
Shunting gear at F2
4
Shunting gear at F3
8
Shunting gear at F4
16
Acceleration and brake delay
to be switched at F3
32
Acceleration and brake delay
to be switched at F4
64
Parameter of
50
23
0 ... 255
load control KP
(40)
= Proportional component of
the load control.
The parameter KP defines the basic speed (for LD-G-33 only). A too small value
à
locomotive too slow. A too high value
à
heavy shaking of the locomotive.
Parameter of
51
24
0 ... 255
load control KI
(20)
= Integral component of the
load control.
The parameter KT provides the fine tuning of the load control (for LD-G-33 only).
The value has to be adjusted in very small steps.
A too high value
à
heavy shaking of the locomotive.
Parameter of
52
25
0 ... 255
load control KD
(50)
= Differential component of
the load control
The parameter KD retards the transforming of the load control (for LD-G-33 only).
A too small value
à
shaking of the locomotive.
A too high value
à
vibrating of the locomotive.