(function key F1): The proportional component of the load control
ensures the difference between the set and the present value being as
small as possible. It cannot have the value „0“ at any time.
KI
(function key F2): The integral component of the load control
ensures the remaining difference between the set and the present
value being reduced to 0.
KD
(function key F3): The differential component of the load control
ensures that the control is not converted too quickly. Shaking and
vibrating would be the consequence.
Setting the parameters of the load control:
First switch off all
auxiliary functions. Then switch on the function F4 and start the
standard operation. Find the speed level where the locomotive shakes.
Keep the setting of the speed knob and switch off the function F4. The
locomotive continues to drive, but you cannot influence the speed from
the speed knob.
Next you have to set the speed knob to speed level 7 (120 on the
Märklin* Central Unit 6021). Select the parameter you want to modify
by switching on the assigned function key.
For all parameters is valid that: Speed level 7 is equivalent to the saved
value of the parameter. By setting a lower speed level the value of the
parameter is reduced, by setting a higher speed level it is enlarged. The
set value takes effect immediately and therefore can be checked
directly on the driving locomotive. As soon as the parameter is set as
desired, confirm your setting by switching the function key „function“
on and off once.
Set the speed knnob to speed level 7 in order to set the value of the
parameter saved before. Switch off the assigned function and continue
with modifying the next parameter of the load control if necessary. As
soon as all modifications are made, you can close the programming
mode by disconnecting the locomotive.